Page 17
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVALS:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Part #
Change time Frame
Sediment Filter, 5 Micron, 9 7/8”:
#FPMB5-978
6 Months
Carbon Block, 5 Micron, 9 3/4”:
#WCBCS975
6 Months
In-line Carbon Filter:
#AICRO
12 Months
TFC Membrane, 50GPD @60PSI:
#W-1812-50
2 to 5 years
Depending on water chemistry, water temperature, and water pressure Watts R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion of
the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage
tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.
Phone: 800-659-8400 Fax: 800-659-8402 www.watts.com
GENERAL USE CONDITIONS:
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
is micro biologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
3. Operating Water Pressure:
Maximum: 100 psi (7.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
4. pH
2 to 11
5. Maximum iron present in incoming feed water supply must be less than 0.2 ppm.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Watts Water Technologies
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
GTS450S / GTS550S
Avg. In.
Avg. Eff.
% Reduction pH
Pressure
Max Eff.
Inf. challenge
Max Allowable
(mg/L)
(mg/L)
mg/L
concentration
concentration
mg/L
mg/L
Bacteria*
99.9999%
Virus*
99.99%
Arsenic (Pentavalent)
334.62 ug/L
5.039 ug/L
98.4%
50psi
19 ug/L
0.30±10%
0.010 mg/L
Barium Reduction
10.2
0.13
98.7%
7.24
50psi
0.27
10.0±10%
2.0
Cadmium Reduction
0.031
0.0001
99.7%
7.49
50psi
0.0009
0.03±10%
0005
Chromium (Hexavalent)
0.30
0.006
98.0%
7.24
50psi
0.013
0.03±10%
0.1
Chromium (Trivalent)
0.30
0.003
99.0%
7.24
50psi
0.008
0.03±10%
0.1
Copper Reduction
3.0
0.04
98.7%
7.64
50psi
0.06
3.0±10%
1.3
Cysts
222,077#/ml
10 #/ml
99.99%
50psi
58 minimum 50,000/mL
N/A
Fluoride Reduction
8.0
0.33
95.9%
7.49
50psi
0.47
8.0±10%
1.5
Lead Reduction
0.15
0.004
97.3%
7.49
50psi
0.008
0.15±10%
0.0107
Nitrite and Nitrate
29.2
6.6
77.3%
7.64
50psi
10.0
3.0±10%
10.0
Nitrate Reduction
26.3
6.1
76.8%
7.64
50psi
10.0
3.0±10%
10.0
Nitrite Reduction
2.8
0.5
82.1%
7.64
50psi
0.77
3.0±10%
1.0
Perchlorate
0.10
0.003
96.5%
7.39
50 psi
0.005 mg/L
0.10±10%
0.006
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
0.10
<0.001
99.0%
50psi
<0.001
0.10±10%
0.05
TDS
764
36
95.2%
7.84
50psi
50.0
750±40mg/L
187
Turbidity
81 NTU
0.15 NTU
99.8%
50psi
0.28 NTU
11±1 NTU
0.5 NTU
Recovery - 16.34%
Daily Production Rate - 17.32 GPD
Efficiency - 8.91%
*independantly tested and verified by Bio Vir Laboratories