Page 7
Typical RO Faucet Installation
3/8” BLUE TUBING FROM
RO MODULE
1/4” RED LINE TO
RO MODULE
3/8” BLUE TUBING FROM
RO MODULE
Drinking Feed Tube Connection
Non Air Gap Faucet
Locate the 3/8” threaded quick connect fitting in
the parts bag. After the faucet has been mounted,
thread the fitting on the to faucet stem. Connect the
3/8” blue feed tube to the 3/8” quick connect fit
-
ting on the faucet stem. The final polishing filter is
clipped on to the top of the RO membrane
housing. Attached to the polishing filter is a 3/8”
quick connect elbow fitting. Attach the open end of
the 3/8” blue tubing from the RO faucet to the 3/8”
quick connect elbow on the polishing filter.
With Non Air-Gap faucets this will be the only tube
connected to the RO faucet.
Air Gap Faucet
Follow the drinking feed tube connection instruc-
tions above. Installation instructions for the two
remaining tubes will be outlined in the upcoming
pages.
3/8” FAUCET CONNECTOR
LOCK WASHER
COUNTER TOP/SINK
ESCUTCHEON PLATE
BLACK RUBBER
WASHER
3/8” BLUE TUBING FROM
RO MODULE
3/8” FAUCET CONNECTOR
LOCK WASHER
COUNTER TOP/SINK
ESCUTCHEON PLATE
BLACK RUBBER
WASHER
3/8” LINE TO DRAIN
SADDLE