background image

Hybrid mode of energy reservation and distribution

TYPICAL CONNECTION SCHEMATICS

OWNER’S MANUAL - WATTS

Multi-block mode for maximum autonomy and protection from blackouts

29

Summary of Contents for WBX 1

Page 1: ...OWNER S MANUAL WATTS WBX 1 ...

Page 2: ......

Page 3: ...ERRORS OR PROBLEMS IN THE INSTRUCTION To report any inaccuracies or omissions in this manual send an email to manual wattsbattery com ATTENTION DO NOT THROW THE DEVICE WHILE IN SHIPMENT WARNING This product is ranked as a S2 uninterruptible power supply system When used at home this product may interfere with the operation of other technical equipment due to industrial radio interference In this c...

Page 4: ...CATIONS OF THE WATTS 13 EQUIPMENT 15 CONNECTION AND OPERATION 18 Quick start 19 Setting up an Internet connection 24 Recommendations for choosing the amount of WATTS and the relative battery life 26 Installing a stack multiple WATTS 28 The connection of photovoltaic panels 30 FIX A PROBLEMS 30 TYPICAL CONNECTION SCHEMATICS 30 WARRANTY CONDITIONS 30 3 ...

Page 5: ...AUTION indicates a hazardous situation which if not avoided could result in damage to the equipment SAFETY PRECAUTIONS Do not disassemble the device body frame there is dangerous voltage inside the device The built in rechargeable battery may contain hazardous voltage parts even when the device is unplugged Do not immerse WATTS or its components in water or other fluids Do not use cleaning solvent...

Page 6: ...ow 20 degrees Celsius at a relative humidity level of more than 90 during condensation of moisture in the room in direct sunlight or near heating elements in places with insufficient ventilation cooling in places with increased vibration in gas distribution points Failure to comply with the operating conditions of the device will shorten the battery life Do not use with medical equipment and life ...

Page 7: ...the 2 4 GHz frequency bands To avoid equipment malfunctions or slow operation due to radio wave interference when using the integrated wireless LAN equipment never place the module near other devices that use 2 4 GHz signals such as other wireless LAN devices microwave ovens and remote antennas The cable connected to WATTS must not exceed 9 meters in order to maintain stability in the operation of...

Page 8: ... network when electricity prices are low transfers power during a period of increased tariffs supplies the power grid during a power outage and automatically optimizes home energy Thus WATTS maximizes the consumption of solar energy and reduces costs In the application on your smartphone you can familiarize yourself with the predefined modes remotely control and analyze the power supply of your ho...

Page 9: ...ssion of the power supply network bypass 7500 W Maximum AC input terminal input 50 А Operating voltage range from PV panels 30 95V DC Maximum DC Power Supply from PV Panels 1000 W Maximum DC Current per MPPT Controller 30А SPECIFICATIONS OUTPUT POWER SPECIFICATIONS INPUT POWER SPECIFICATIONS Housing outlet 2 pcs Type F SHUKO or Type B US 5V DC Connectors 4 pcs USB Input and output ports for connec...

Page 10: ...ons H x W x D 140 x 460 x 360 mm 5 5 x 18 1 x 14 1 in Operating Usage Temp 10 40 С 14 104 F Recommended Temp Use 10 25 C 50 77 F Storage temperature 10 40 С 14 104 F Noise Level 1 m 35 dBa at 30 C 86 F Maximum working height 3000 m 9842 ft Relative humidity 5 80 Protocols 802 11 b g n 802 11n up to 150 Mbps Frequency Range 2 4 2 5 GHz Bluetooth version 4 0 GENERAL COMMUNICATION Guarantee for regis...

Page 11: ...overs AC 230 120 volts 3 Cover for USB connectors 5 Interblock information contacts Bottom view 6 Bottom of the interblock connector cover of the interblock connector 7 Screws for protective cover steel color 8 Interblock information contacts 9 Information sticker 10 Device supports 2 3 4 5 6 7 8 9 10 460 mm 18 1 in 360 mm 14 2 in 140 mm 5 5 in 10 ...

Page 12: ...ith terminal power 20 Protective switch of the battery pack APPEARANCE AND INDICATIONS OF WATTS OWNER S MANUAL WATTS Front view 11 15 Ventilation compartments 12 Energoblok start button Switch on off 13 Charge indication 100 80 60 40 20 14 Multi function indicator ring Red error yellow normal operation blue Bluetooth connection flashing blue Bluetooth search mode yellow flashing loading communicat...

Page 13: ...to the external power grid Power cable terminal connection external generator 23 Indicator for connecting to the PV supply panels 24 Internet connection indicator 25 Protective Interblock cover 26 The indicator of the increased temperature 27 Internal error indicator 28 Indicator of excessive load on the block 1500 W max US version 2200 W max EU version Side view 22 24 25 28 31 12 ...

Page 14: ...le 1 pc Power cable 1 pc Allen key 2 0 x 52 1 pc Allen key 2 0 x 52 1 pc Allen key 2 0 x 52 1 pc Documents and manual 1 pc Documents and manual 1 pc Documents and manual 1 pc Backpack 4 pc 250W solar panels PV 1 pc Device for protection from pulsed discharges EQUIPMENT OWNER S MANUAL WATTS 13 ...

Page 15: ...g the supplied cable 19 Or connect WATTS to the switchboard see the corresponding chapter At the moment of connection there may be an instant spark this is normal do not pull the plug Make sure that all power cables are connected correctly by pressing the power button 12 After the first power up wait until WATTS is fully charged 13 and only then connect the load devices Connect the load 2 4 which ...

Page 16: ...carrier may charge you extra for downloaded traffic WATTS Battery 3 download link WATTS Battery 3 download link 1 2 1 2 3 1 2 1 2 3 STEP 1 STEP 2 CONNECTION AND OPERATION OWNER S MANUAL WATTS 1 Open the app and tap 2 Double click on the power button WATTS The button 14 should flash blue 1 After synchronization and detection WATTS will appear in the list 2 You can see the charge percentage as well ...

Page 17: ... STEP 3 STEP 4 CONNECTION AND OPERATION OWNER S MANUAL WATTS 1 You are now on the main page of WATTS where you can view the actual energy distribution model 2 Next you need to select the settings section 1 In the settings menu select the WI FI section 16 ...

Page 18: ...incorrectly the device will not connect to the Internet 3 After entering the details click OK 1 Next in the settings menu click Connect to the cloud 2 If everything is done correctly the successful shortcut will appear for a moment The indicator 19 should turn yellow after a while Please also ensure that the Wi Fi Internet connection is paid and active STEP 3 STEP 4 Successful 2 1 2 3 1 Successful...

Page 19: ...2 4 4 8 5 6 6 4 7 2 8 2 kW 1 2 1 8 2 4 3 3 6 4 2 4 8 5 4 6 2 5 kW 0 96 1 44 1 92 2 4 2 8 3 3 3 84 4 32 4 8 3 kW 0 8 1 2 1 6 2 2 4 2 8 3 2 3 6 4 4 kW 0 9 1 2 1 5 1 8 2 1 2 4 2 7 3 5 kW 0 8 0 9 1 2 1 4 1 68 1 92 2 1 2 4 6 kW 0 8 1 1 2 1 4 1 6 1 8 2 7 kW 0 85 1 1 2 1 3 1 5 1 7 8 kW 0 8 0 9 1 05 1 2 1 35 1 5 9 kW 0 8 0 9 1 1 2 1 3 10 kW 0 84 0 9 1 1 2 11 kW 0 8 0 87 0 98 1 12 kW 0 8 0 9 1 13 kW 0 83 0...

Page 20: ...hould not exceed 2 meters 3 ft The first block from the ground is always a master Open the terminal ports 18 with a hex key AC single phase 230 V out 230 V in or 120V 120V as shown in the image Check that the safety switch 20 is switched off Make sure that no wires are connected to WATTS Keep an eye on the unscrewed covers The terminal connector s covers must be removed from the master only Connec...

Page 21: ...re you need to disconnect the stack make sure to install the covers in the initial position use only the original steel color screws for the lower cover otherwise the block will not turn on When assembling pay attention to the color of the screws Place the covers 1 6 on the magnetic holder 17 as shown Do not tear off the flexible tabs Connection and operation OWNER S MANUAL WATTS STEP 3 STEP 4 Ins...

Page 22: ...preparatory steps 1 Turn off the main switch in the distribution network make sure that there is no voltage at the input 2 Provide the connection line with a circuit breaker based on the minimum wire cross section in the network and the rated load 3 Determine the cross section of the cable three wire copper based on the total power of the connected load Incorrectly selected characteristics of a ca...

Page 23: ... the distance from the switchboard 5 Expose the cable taking into account that the bare ends of each cable should not exceed 10 mm 0 39 in at both ends and press the cable as shown 6 Connect each cable PE N L to the module as shown in the figure When using a multi core cable use ferrules to connect The screwdriver forcefully penetrates the rectangular hole It is not allowed to connect the power su...

Page 24: ... energy units are fully charged 13 and only then use the connected load devices Do not use frame outlets on the block 2 Connect a load that does not exceed 1500 W for 230 V and 1000 W for 120 V per WATTS in case of battery operation bypass no more than 7000 W per block In the event of an overload WATTS will be disabled in an emergency Connection and operation OWNER S MANUAL WATTS STEP 9 Installing...

Page 25: ...ch We recommend that you refer to the diagram Do not connect photovoltaic panels with a power of more than 250W directly to WATTS use lightning protection devices SPD with varistors Do not exceed 1 kW of photovoltaic panel power per WATTS All plug in panels must be identical to each other The voltage level of the open circuit may vary and depends on the environment Connection and operation OWNER S...

Page 26: ...o the photovoltaic panels with a sealed MC4 connector Ground the photovoltaic panels Observe the polarity of the cable lines Use a good quality cable The screwdriver forcefully penetrates the rectangular hole Connection and operation OWNER S MANUAL WATTS The connection of photovoltaic panels STEP 3 STEP 4 If everything is done correctly the indicator 23 will turn green on a Sunny day Connect a loa...

Page 27: ...an 1 5kW The device is discharged and not connected to source of energy Charge the device to do this connect the device to an energy source mains solar panels The power button blinks yellow Download Remote Monitoring System Wait 60 seconds if the situation has not changed contact the service center The red indicator on the top panel flashes WATTS Battery overloaded Turn off the device while holdin...

Page 28: ...connected load and restart the module There are popping sounds inside the device The fuse went off Stop using the module Disconnect the device by opening the circuit breaker in the handle of the module then disconnect the device from the network Then contact your service center for further advice The device s indicator light started flashing different colors at different intervals after touching i...

Page 29: ... and a housing outlet TYPICAL CONNECTION SCHEMATICS OWNER S MANUAL WATTS Connection to the electric power system for automatic switching and backup of electricity Connection to the electric power system for automatic switching and backup of electricity 28 ...

Page 30: ...Hybrid mode of energy reservation and distribution TYPICAL CONNECTION SCHEMATICS OWNER S MANUAL WATTS Multi block mode for maximum autonomy and protection from blackouts 29 ...

Page 31: ... received in good condition I have read and agree with the terms of the warranty Seller Details Seller name Address Telephone E mail Support service Сountry E mail Site Telephone Schedule Россия support wattsbattery org wattsbattery com 7 495 008 29 14 10 00 19 00 Monday Friday USA 1 775 525 03 01 EU 3 572 586 86 34 Your carrier may charge for calls from other regions and countries 30 ...

Page 32: ...serial number of the product Damage or lack of a marking sticker can cause a longer service and repair period Devices of models WBX 1 and higher are equipped with modern communication and consumer information components For communication a permanent Internet connection via Wi Fi is used make sure that the turned on device is connected to your Internet connection via Wi Fi follow the instructions s...

Page 33: ...e of the product replacement of batteries filters indication lamps cleaning of internal components replacement of the housing etc at the initiative of the consumer outside the scope of warranty is carried out for an additional fee at Authorized Service Centers Warranty Limitations The warranty and free service does not apply to the device if its drawbacks appeared due to 1 Violation by the consume...

Page 34: ...04 lead All rechargeable and storage batteries should be disposed of separately from household waste in specialized collection points designated by government or local authorities Disposal of old equipment will help prevent potentially harmful effects on the environment and human health For more detailed information about the disposal of equipment contact the city administration the disposal servi...

Page 35: ......

Page 36: ...WATTS OWNER S MANUAL www wattsbattery com manual manual wattsbattery com ...

Reviews: