CHAPTER 8:
SUMMARY OF PARAMETER SETTINGS
8-6
Para-
meter
Explanation Settings
Factory
Setting
Actual
Setting
4-11
Acceleration /Deceleration
speed of constant up/down
frequency
d0 to d1000 Hz/sec
d1
Group 5: Multi-Step Speed and PLC Parameters
Para-
meter
Explanation Settings
Factory
Setting
Actual
Setting
5-00 1
st
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-01 2
nd
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-02 3
rd
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-03 4
th
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-04 5
th
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-05 6
th
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-06 7
th
Step Speed Freq.
d0.0 to d400 Hz
d0.0
5-07 PLC Mode
d0: Disable PLC Operation
d1: Execute one program cycle
d2: Continuously execute program cycles
d3: Execute one program cycle step by
step
d4: Continuously execute one program
cycle step by step
d5: Disable PLC operation, but can set
direction of 1
st
speed to 7
th
speed
d0
5-08 PLC Forward/ Reverse
Motion
d0 to d255 (0: FWD 1: REV; binary
coded!)
d0
5-09 Time Duration Step 0
d0 to d65500 Sec
d0
5-10 Time Duration Step 1
d0 to d65500 Sec
d0
5-11 Time Duration Step 2
d0 to d65500 Sec
d0
5-12 Time Duration Step 3
d0 to d65500 Sec
d0
5-13 Time Duration Step 4
d0 to d65500 Sec
d0
5-14 Time Duration Step 5
d0 to d65500 Sec
d0
5-15 Time Duration Step 6
d0 to d65500 Sec
d0
5-16 Time Duration Step 7
d0 to d65500 Sec
d0