Group 2 Operation Method Parameters
Para-
meter
Explanation Settings
Factory
Setting
Actual
Setting
2-00 Source of Frequency
Command
d0: Master Frequency input determined by
digital keypad. (record the frequency of
power loss and it can do analog overlap
plus)
d1: Master Frequency determined by analog
signal DC 0V-10V (external terminal AVI).
(won’t record the frequency of power loss
and it can’t do analog overlap plus)
d2: Master Frequency determined by analog
signal DC 4mA - 20mA (external terminal
AVI). (won’t record the frequency of power
loss and it can’t do analog overlap plus)
d3: Master Frequency determined by
Potentiometer on the digital keypad.
(won’t record the frequency of power loss
and it can do analog overlap plus)
d4: Master Frequency operated by RS-485
serial communication interface. (record
the frequency of power loss and it can do
analog overlap plus)
d5: Master Frequency operated by RS-485
serial communication interface. (won’t
record the frequency of power loss and it
can do analog overlap plus)
d1
2-01 Source of Operation
Command
d0: by Digital Keypad
d1: by external terminals, keypad STOP
enabled
d2: by external terminals, keypad STOP
disabled
d3: by RS-485 communication interface,
keypad STOP enabled
d4: by RS-485 communication interface,
keypad STOP disabled
d1
2-02 Stop Method
d0: Ramp Stop
d1: Coast Stop
d0
2-03 PWM Carrier Frequency
d3: 3KHz
d4: 4KHz
d5: 5KHz
d6: 6KHz
d7: 7KHz
d8: 8KHz
d9: 9KHz
d10: 10KHz
d5
2-04 Reverse Operation
d0: Enable REV
d1: Disable REV
d0
2-05 Loss of ACI Signal
d0: 0 Hz reference, no error stop
d1: Stop the frequency output – error “EF”
d2: Last ACI input command
d1
2-06 Analog Auxiliary
Frequency Operation
d0: Disable
d1: AVI
d2: ACI
NOTE: Set Jumper J1 accordingly!
d0