Function
Input
or
output
Configurable
Signal response
ANALOG 2
ANALOG 2
No
13.4
Standard - 25 way D: power supply limits
Signal
Connector
Pin numbers
Voltage
Load
5V Ref
Upper
18, 19
5V @ no load
Total of all pins 10mA max
Lower
9, 19, 23
12V Ref
Upper
21
12V @ no load
Total of all pins 10mA max
Lower
25
10V Ref
Lower
21
10V @ no load
Minimum load 4K7 ohms
VAUX
Upper
21
Nom 22V (18-35V
unregulated)
10mA Nom (100mA fused)
13.5
N - Modules Standard and SCADA
The recommended cable and cable glands must be used for the IP66 (NEMA
4X) version of the pump; otherwise ingress protection may be impaired.
Ensure that the module cover is correctly secured at all times by all screws
supplied. Failure to do so may compromise the IP66 (NEMA 4X) protection.
Ensure that unused openings on the module are sealed using the blanking
plugs provided. Failure to do so may compromise the IP66 (NEMA 4X)
protection.
32