13.1
Pump external interface parameters
Parameter
Limits
Units
Comment
Sym Min Nom Max
Digital input voltage high
VD
IH
5
24
V
Leak, Stop, Pressure,
Frequency
Digital input voltage low
VD
IL
0
0.8
V
Leak, Stop, Pressure,
Frequency
Digital input voltage absolute
maximum
VD
in
-30
30
V
Non operational
Digital input resistance
RD
in
10
110
kΩ
110K for ≤ 5V
Frequency range
F
max
1
1000
Hz
Flow sensor use
Analogue input, voltage mode
VA
in
-15
10
30
V
0-10V range (100R source
impedance)
Analogue input, voltage mode
RVA
in
34.4
kΩ
±3%
Analogue input measurement
range
I
in
0
25
mA
Analogue input current absolute
maximum
IA
in
-50
28
mA
Dissipation limit
Analogue input voltage absolute
maximum
VA
in
0
7.0
V
Dissipation limit
Analogue input resistance
RI
IN
250
270
Ω
250R Sense Res.
Analogue input filter bandwidth
BW
67
Hz
-6dB Bandwidth
22V supply output
V
aux
18
30
V
Un-regulated
24V isolated supply output
V24
24
22V/24V supply load current
80
mA
Self-resetting fuse
24
m-630en-en-01
Summary of Contents for 630 Series
Page 35: ...13 7 Network topology Star network Ring network m 630en en 01 35...
Page 83: ...m 630en en 01 83...
Page 105: ...22 Help 22 1 Help Select Help from the main menu to access the help screens m 630en en 01 105...
Page 131: ...32 Publication history m 630en 01 530 EN pump First published 04 2020 m 630en en 01 131...