![Watson Marlow Pumps 630 Series Installation, Operating And Maintenance Manual Download Page 32](http://html1.mh-extra.com/html/watson-marlow-pumps/630-series/630-series_installation-operating-and-maintenance-manual_3761990032.webp)
Power supply options
The NEMA terminal board is available with an isolated power supply option. This has a 24V isolated
power supply (maximum output load 80mA), U1, fitted. As shown below, U1 completely separates the
terminal 24V and 0V from the pump internal supplies.
This may be used if the sensor requires an isolated supply or has a 4-20mA output which cannot be used
with the ground connected load resistor within the pump.
22V
0VA
ISO.24V
0VA
U1
22V
0VA
U1
22V
ISO.0V
1.
2.
1. Without isolated power supply option (N Module) 2. With isolated power supply option (F Module)