11.4
Ethernet M12 connector screen connection
1.
By default the body and cable screen of the M12 Ethernet connectors are insulated from the metal
body of the NEMA module and mains ground. This is in accordance to The EtherNet/IP™
specification for use in industrial automation systems using EtherNet/IP™.
2.
If there is a requirement to connect the M12 body and cable screen (A) to Mains earth for EMC or
Ethernet TCP reasons then the default plastic M12 mounting collar (MN2934T) can be replaced by
a stainless steel version (MN2935T). Ensure the M12 O-ring and sealing washer are seated correctly
to maintain IP66 sealing.
m-630en-en-01
21
Summary of Contents for 630 Series
Page 35: ...13 7 Network topology Star network Ring network m 630en en 01 35...
Page 83: ...m 630en en 01 83...
Page 105: ...22 Help 22 1 Help Select Help from the main menu to access the help screens m 630en en 01 105...
Page 131: ...32 Publication history m 630en 01 530 EN pump First published 04 2020 m 630en en 01 131...