![Watson Marlow Pumps 630 Series Installation, Operating And Maintenance Manual Download Page 12](http://html1.mh-extra.com/html/watson-marlow-pumps/630-series/630-series_installation-operating-and-maintenance-manual_3761990012.webp)
If hazardous fluids are to be pumped, safety procedures specific to the
particular fluid and application must be put in place to protect against injury
to persons.
This product does not comply with the ATEX directive and must not be used in
explosive atmospheres.
Ensure the chemicals to be pumped are compatible with the pumphead,
lubricant (where applicable), tubing, pipework and fittings to be used with
the pump. Please refer to the chemical compatibility guide which can be
found at:
. If you need to use the pump with any
other chemical please contact Watson-Marlow to confirm compatibility.
There are moving parts inside the pumphead. Before opening the tool-
unlockable guard or tool-unlockable track, ensure that the following safety
directions are followed:
1.
Ensure the pump is isolated from the mains power.
2.
Ensure that there is no pressure in the pipeline.
3.
If a tube failure has occurred, ensure that any fluid in the pumphead
has been allowed to drain to a suitable vessel, container or drain.
4.
Ensure that appropriate Personal Protective Equipment (PPE) is worn.
Primary operator protection from rotating parts of the pump is provided by
the pumphead safeguard. Note that safeguards differ, depending on the type
of pumphead. See the pumphead section of the manual.
12
m-630en-en-01
Summary of Contents for 630 Series
Page 35: ...13 7 Network topology Star network Ring network m 630en en 01 35...
Page 83: ...m 630en en 01 83...
Page 105: ...22 Help 22 1 Help Select Help from the main menu to access the help screens m 630en en 01 105...