Param
No.
EDS Values
Read/Write
Default
Value
(EDS)
Parameter
Range
Comments
43
Reverse
Read
0
0-1
(False/True)
If set the pump is set to
run Counter-Clockwise
44
Running
Read
0
0-1
(False/True)
Set if the pump is running
45
LeakDetected
Read
0
0-1
(False/True)
Set if a leak is detected
46
MotorStallError
Read
0
0-1
(False/True)
If Set the pump has a
Motor Stall Error. Please
follow onscreen
instructions
47
MotorSpeedError
Read
0
0-1
(False/True)
If set the pump has an
over current error. Please
follow onscreen
instructions
48
OverCurrentError
Read
0
0-1
(False/True)
If set the pump has an
over current error. Please
follow onscreen
instructions
49
OverVoltageError
Read
0
0-1
(False/True)
If set the set the pump has
an over voltage error.
Please follow onscreen
instructions
50
Guard/Interlock
Read
0
0-1
(False/True)
If set then the guard has
been opened. Please
follow onscreen
instructions to clear.
51
FlowHi-LoActive
Read
0
0-1
(False/True)
If set then the flow sensor
low warning is active
52
FlowLo-LoActive
Read
0
0-1
(False/True)
If set the flow sensor low
alarm is active
53
PressureHi-LoActive
Read
0
0-1
(False/True)
If set the pressure low
warning is active
m-630en-en-01
61
Summary of Contents for 630 Series
Page 35: ...13 7 Network topology Star network Ring network m 630en en 01 35...
Page 83: ...m 630en en 01 83...
Page 105: ...22 Help 22 1 Help Select Help from the main menu to access the help screens m 630en en 01 105...
Page 131: ...32 Publication history m 630en 01 530 EN pump First published 04 2020 m 630en en 01 131...