Watlow DIN-A-MITE C User Manual Download Page 20

20

WATLOW DIN-A-MITE Style C User's Manual

The Watlow DIN-A-MITE is warranted to be
free of defects in material and workmanship for
36 months after delivery to the first purchaser
for use, providing that the units have not been
misapplied. Since Watlow has no control over
their use, and sometimes misuse, we cannot
guarantee against failure. Watlow's obligations
hereunder, at Watlow's option, are limited to
replacement, repair or refund of purchase price,
and parts which upon examination prove to be
defective within the warranty period specified.
This warranty does not apply to damage
resulting from transportation, alteration,
misuse, abuse or improper fusing.

Returns

Warranty

1.

Call Watlow Customer Service, (507) 454-
5300, for a Return Material Authorization
(RMA) number before returning any item
for repair. We need the following
information:

• Ship to address
• Bill to address
• Contact name
• Phone number
• Method of return shipment
• Your P.O. number
• Detailed description of the problem
• Any special instructions
• Name and phone number of the person

returning the product

2.

Prior approval and an RMA number, from
the Customer Service Department, is
required when returning any unused
product for credit. Make sure the RMA
number is on the outside of the carton, and
on all paperwork returned. Ship on a
Freight Prepaid basis.

3.

After we receive your return, we will
examine it and try to verify the reason for
the return.

4.

In cases of manufacturing defect, we will
enter a repair order, replacement order or
issue credit for material returned.

5.

To return products that are not defective,
goods must be in new condition, in the
original boxes and they must be returned
within 120 days of receipt. A 20 percent
restocking charge is applied for all returned
stock controls and accessories.

6.

If the unit is unrepairable, it will be
returned to you with a letter of explanation.

7.

Watlow reserves the right to charge for no
trouble found (NTF) returns.

The DIN-A-MITE C User’s Manual is
copyrighted by Watlow, Inc., © January
2015, with all rights reserved.

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for DIN-A-MITE C

Page 1: ...DIN A MITE power controller includes single phase 3 phase 2 leg and 3 phase 3 leg 120 to 600V ac operation Current switching capabilities range from 30 to 80A depending on the model ordered See the o...

Page 2: ...gle with current limit Input Control Signal Types P and L are not CE approved UL 50 Type 4X Enclosure and UL ANSI ISA 12 12 01 Temperature Code T4A The through wall heatsink package is suitable for us...

Page 3: ...ed 0 to 100 08 5362 Alarm option is not available on phase angle type P or type L Resolution Better than 0 1 of input span with respect to output change Control Mode Zero Cross Input Control Signal Ty...

Page 4: ...se only P 0 to 5 Phase angle DC1 only Alarm 0 only Single phase only S 0 to 5 Single cycle variable time base Select one of the following input options for L P S 0 to 5 0 4 to 20mA 1 12 to 20mA for In...

Page 5: ...soft start and line voltage compensation This model will work with a linear voltage input a linear current source input or a potentiometer input This is single phase only Alarms not available on phase...

Page 6: ...nto place If the DIN A MITE does not snap into place check to see if the rail is bent 4 Mount the cooling fins vertically 3 WARNING Only authorized and qualified personnel should be allowed to install...

Page 7: ...flow and wire bending radius 102 mm 4 0 in clearance for air flow and wire bending radius 150 mm 5 89 in Rail Release Tab pull down 44 mm 1 73 in 57 mm 2 26 in 127 mm 5 00 in 79 mm 3 10 in 102 mm 4 0...

Page 8: ...atsink 4 Mount the heatsink vertically Torque to 2 26 to 2 82 Nm 20 to 25 in lb Ground lug 2 8 GA M5 0 8 by 10 mm 8 M5 Internal Tooth Lock Washer 8 included 178 mm 7 00 in 122 mm 4 81 in Panel Opening...

Page 9: ...5 16 17 18 19 20 1 2 3 4 5 6 Signal Alarm Gain Bias Open Heater Limit Adjustment Potentiometers 4 to 20mA dc Input 7 8 9 4 5 to 32V dc Input 7 8 9 Zone 1 Zone 2 Zone 3 Note Use tool Bourns H91 to adju...

Page 10: ...Zone 2 Zone 3 1k Potentiometer Input Use with 0 to 5V dc Input 4 to 20mA and Linear Voltage Input 1 3 For models DC 1 2 3 _ _ _ L P S _ _ _ _ _ Auto and Manual Input Application 4 to 20mA dc signal fr...

Page 11: ...power 4 Turn on the power to the DIN A MITE 5 Gradually increase the input signal 6 Adjust the current limit potentiometer clockwise until the current to the load is measurable The current limit indic...

Page 12: ...o 20mA output or 5V for 0 to 5V output 2 Adjust the open heater alarm adjustment potentiometer until the alarm indicator light on the front panel is full on with no intermittent cycling 3 Slowly adjus...

Page 13: ...ge to equipment and personal injury or death NOTE The shorted SCR alarm option is not available with phase angle units Torque Guidelines Properly torque line and load terminals to 2 7 Nm 24 in lb Reto...

Page 14: ...jury or death Torque Guidelines Properly torque line and load terminals to 2 7 Nm 24 in lb Retorque after 48 hours to minimize wire cold flow Retorque line and load terminals every 3 to 6 months L1 L2...

Page 15: ...15 16 17 18 19 20 Gain Bias Open Heater Limit ALM ALM CT1 CT1 CT2 CT2 CT3 CT3 4 5 6 1 2 3 Signal Alarm Zone 1 Zone 2 Zone 3 Heater 2 Heater 3 Heater 1 L2 L2 L2 Limit Control Contacts if required Semic...

Page 16: ...f you plan to wire multiple DIN A MITE alarm outputs you need to include an intermediate relay for each DIN A MITE used System Wiring Example Alternative Latching Alarm Circuit If there is a need for...

Page 17: ...SCR alarm will energize a triac on board the DIN A MITE output An open heater or partial open heater state is detected when a command signal is present and a reduced or no output current is detected T...

Page 18: ...oltage Variations EN 61000 3 2 2009 Harmonic Current Emissions Reviewed to IEC 61000 3 2 2014 EN 61000 3 3 2013 Voltage Fluctuations and Flicker3 16A EN 61000 3 11 2000 Voltage Fluctuations and Flicke...

Page 19: ...to death for personnel WARNING All filter installation and wiring must be performed by qualified personnel and conform to local and national electrical codes In line power filters have been shown to p...

Page 20: ...number Detailed description of the problem Any special instructions Name and phone number of the person returning the product 2 Prior approval and an RMA number from the Customer Service Department is...

Reviews: