Waters Network Systems
2800M/MR User’s Manual
Page 139
Command
Syntax
Description
Argument
Possible
Value
active: set the LACP
to active mode;
passive: set the
LACP to passive
mode
Show aggtr-
view
show aggtr-
view
Used to display the aggregator
list
None
None
Show lacp-
config
show lacp-
config
Used to display the value of the
LACP priority
None
None
Show lacp-
detail
show lacp-
detail
Used to display the detailed
information of the LACP group
<aggtr>:aggregator,
available from 1 to 26
<aggtr> 1 to 26
Show status
show status
Used to display the aggregator
status and the settings of each
port
None
None
VLAN
Del port-group
del port-group
<name>
Used to delete the port-based
VLAN group
<name>: VLAN group
to be deleted
<name>: port-
VLAN name
Del tag-group
del tag-group
Used to delete the tag-based
VLAN group
<vid>: VLAN group to
be deleted
<vid>: 1 to
4094
Disable
double-tag
disable double-
tag
Used to disable the double-tag
None
None
Disable drop-
untag
disable drop-
untag <range>
Used to disable the drop-untag
<port-range>: ports to
be set, syntax 1, 5-7,
available 1 to 26
<range>: 1 to
26
Disable svl
disable svl
Used to disable independent
VLAN learning
None
None
Disable
symmetric
disable
symmetric
Used to keep frames from
being dropped from the non-
member port
None
None
Enable
double-tag
enable double-
tag
Used to enable double tag
None
None
Enable drop-
untag
enable drop-
untag <range>
Used to drop the untagged
frames
<port_range>: ports
to be set, syntax 1, 5-
7, available 1 to 26
<range>: 1 to
26
Enable svl
enable svl
Used to enable shared VLAN
learning
None
None
Enable
symmetric
enable
symmetric
Used to drop frames from the
non-member port
None
None
Set mode
set mode <
port|tag>
Used to switch LVAN mode
between port-based and tag-
based
<por|tag>:port or tag
tag:set tag-based
vlan port:set port-
based vlan
<port|tag>: port
or tag
Set PVID
set pvid
<port_range>
<pvid>
<default_
priority>
Used to set VLAN PVID and
port priority
<port_range>: which
port(s) you want to
set PVID(s).
Syntax
1,5-7, available
from 1 to 26
<pvid>: which PVID
you want to set,
available from 1 to
4094
<port_range>:
1 to 26
<pvid>: 1 to
4094
<default_priorit
y>: 0 to 7