28
Installation & Operation Manual
Copyright © Puretec Pty Ltd 2022
Now programming is completed (if required) you are ready to start the system.
1. Fill the brine tank with ‘water softener’ salt to approximately half full (salt not included).
Minimum start-up amount is 75 kg.
2. Add approximately 40 litres of water to the salt in the brine tank. This is only required
for the initial setup.
Note:
the water level will change, this is normal.
3. Open the nearest tap downstream of the filter system (after the filter system).
4. Allow water to flow through the system slowly, and allow all air to escape out of the
closest tap. Wait until the water is flowing out of the tap and then increase the flow
slowly up to full flow. Allow to run for 5 - 10 minutes.
5. Close the opened tap and check for leaks.
6. Conduct a full manual regeneration.
7. Your system is ready for use.
Start-Up
Set Time of Day
Time of day should only need to be set on installation or when
daylight saving time begins or ends. If the time flashes on & off
after a power loss the time of day should be reset & the CR2032
button battery replaced. Note: All other settings will not require
reprogramming. In the unlikely event of a power loss during a
backwash, when the power is restored, a dry-reset should be
performed (see page 27), followed by a manual regeneration
(refer to above) if convenient.
1. Press "SET CLOCK".
2.
Current Time (hour):
Set hour of the day by using ▲ or ▼.
Press "NEXT" to go to next step.
3.
Current Time (minutes):
Set the minutes of the day using
▲ or ▼. Press "NEXT" to exit Set Clock.
RETURN TO NORMAL MODE
Start-Up
Summary of Contents for Puretec Commercial SOL-2CI Series