5.
Allows selection of one of the following :
• An outside signal to initiate a regeneration; or
• An outside signal to prevent or delay regeneration.
Selection only matters if a connection is made to the two
pin connector labelled DP SWITCH located on the printed
circut board.
• oFF (default) :
Feature not used.
Note:
In a twin alternating system each control must have
a separate dP signal or dP switch. One dP signal or one dP
switch cannot be used for both controls.
• dPon0:
If the dP switch is closed for an accumulative time
of 2 minutes, a regeneration will be signalled to the unit.
• dPdEL:
If the switch is closed for an accumulative time
of 2 minutes a regeneration will occur at the scheduled
delayed regeneration time. Once the dP switch is triggered
the PC board will display REGEN TODAY and switch tanks
immediately. At the delayed regeneration time, the triggered
unit will then regenerate.
• HoLd:
If the dP switch is closed a regeneration will be
prevented from occurring while there is switch closure.
Press NEXT to go to step 6.
6.
Preset to default. (▲ or ▼ buttons can be used to set hard-
ness) Press NEXT to go to step 7.
7.
Preset to default. Press NEXT to go to step 8.
Valve & DP Programming