INSTALLATION AND FLUSHING PROCEDURES 

 

Safety and Installation Guidelines 

Ensure all Local, State, and Federal Laws and Codes including health and safety guidelines are 

met when installing 

Waterlogic

 Equipment.   Only qualified service technicians should attempt 

installation and service of 

Waterlogic

 Equipment.     

 

WARNING!

  

ELECTRICAL SHOCK HAZARD.  

Always unplug (isolate from power supply) to 

prevent electrical shock except where electrical tests are specified.   

 

       WARNING!

  

IMPROPER SUPPLY OR CONNECTION CAN RESULT IS RISK OF SHOCK. 

Connect to a 15 amp, 120V 60Hz properly grounded outlet (GFI is recommended).  Ensure 

polarity is correct and always use a 3-prong outlet.  Consult a qualified electrician if you 

have any questions.     

 

WARNING!

  

USE ONLY Waterlogic SUPPLIED POWER CORD.

  Locate system within 5 feet of 

power supply.  Never use an extension cord or adapter.  Do not use a damaged power cord 

or plug.  Keep power cord out of heavy traffic areas and away from heat sources.  Do not, 

under any circumstances, remove ground prong or alter the power cord.  Never pull the 

power plug from the outlet with a wet hand or allow the plug to get wet.  Failure to use the 

supplied power cord will void UL Certification and Warranty.   

 

CAUTION!

  

INDOOR USE ONLY.   

Never expose to direct sunlight, heat sources, or ambient 

air temperature above 38°C (100°F) or below 2°C (35°F).  Install indoors and keep unit away 

from excessive humidity.  Never expose to freezing temperatures.  Ensure there is adequate 

clearance around the unit to allow refrigeration system condenser to dissipate heat.  

Warmer environments require more clearance around the unit.  Minimum clearance around 

all surfaces of the machine is 2-inches.  Installs where the ambient temperature exceeds 

80°F, require a minimum of 4-inches clearance for proper heat dissipation and efficient 

operation.    

 

CAUTION!

  

USE A WATER PRESSURE REGULATOR. Waterlogic

 will not be responsible for 

injury or damage caused by excessive water pressure.  Operating pressure must be 40 psi to 

60 psi.  Be aware any of potential pressure surges caused by building/municipal pumping 

stations.   

 

CAUTION!

  

USE UV STABILIZED SUPPLY LINES.  

Feed the unit with a potable ambient or 

cold-water supply only.

  

Feed water over 100° F (37°C) can damage the treatment 

components.  Water block devices and external leak detectors are strongly recommended. 

Locate the unit as close to the water supply and the electrical connections as possible.   

 

       WARNING!

  

STORE AND TRANSPORT UNIT EMPTY. 

  

ALWAYS SANITIZE BEFORE USE. 

The unit must be completely drained and sealed before storing to avoid stagnation and 

reduce microbiological contamination (potential bacterial growth).  Sanitize before use to 

eliminate any potential microbiological contaminates

 

 