background image

 

WLH2 Classe

 Manual 

                                                      Page 36 – Revision: 3-2-2021 

Remove Plug 
To Drain 

DRAINING INSTRUCTIONS 

 

 

       WARNING!

  

STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE REUSE. 

The unit must be completely drained and sealed before storing to avoid stagnation and 

reduce microbial growth).   

 

1.

 

The 

WLH2 Classe 

has two main parts to drain, the Still/Sparkling water lines, and the Ice 

Bath. Draining instructions for both parts are below. 

 

2.

 

First, 

SHUT OFF 

the water supply to the machine. 

 

3.

 

Close the valve on the CO

2

 bottle.  

 

4.

 

To drain the 

WLH2 Classe

 Ice Bath, remove the 1/4” plug, that is inserted into the drain 

bulkhead located on the rear of the machine. *

Upon removal of the plug, water will 

begin draining from the ice bath. Have a container prepared to catch the water, or back 

the machine up to a sink or drain basin. 

This operation will take upwards of 20-30min 

to fully drain the ice bath. 

 

         

 

5.

 

To drain the Still water line of the 

WLH2 Classe

, (with the Gas Bottle shut off) disconnect 

the gas line from the CO

2

 inlet. Disconnect the water supply line from the water inlet of 

the unit. Now plug the gas line into the water inlet of the unit and open the valve of the 

Gas Bottle. Simply hold one of the Still Water dispense button to drive water out of the 

still water line until it is empty, and gas is escaping. Shut off the valve of the Gas Bottle 

and reconnect to the CO

2

 inlet of the unit. Once reconnected, do the same for the 

Sparkling Water line, holding the Sparkling dispense button until the dispense line is 

empty, and it begins to gas. 

 

6.

 

Turn the Red Compressor Switch to the 

O=OFF

 position immediately after draining the 

sparkling line.   

 