background image

 

WLH2 Classe

 Manual 

                                                      Page 34 – Revision: 3-2-2021 

Water Supply Port 

CO

2

 Supply Port 

Pre-installation procedures as prescribed in this manual must be performed before installing 

the 

WLH2 Classe

 

Always install indoors and place the 

Waterlogic WLH2 Classe

 

on a firm, flat and stable surface.     

 

 

1.

 

Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the upper 

left section of the rear panel of the 

WLH2 Classe.

  

Waterlogic

 requires the use of a water 

pressure regulator.  Water feed pressure must be between 40-60 psi.   Turn on the water 

supply and check for leaks.

 

 

2.

 

Connect the upper right port to a food grade CO

2

 gas supply, again using a 1/4" supply 

line. Open the tap of the gas bottle and set the pressure to 4 bar (50psi). 

 

 

 

 

 

 

    

 

 

3.

 

Check to ensure that the Red Compressor Power Switch is the 

O=OFF p

osition.  

 

 

NOTE:

  Switches have internal LED that illuminates when placed in 

I=ON

 position. 

 

 

4.

 

Connect the power cord to the back of the 

Waterlogic WLH2 Classe

 

and to a 120 Volt 

supply. Turn Red Compressor Switch to the 

I=ON 

position to power the unit.  

 

5.

 

Water will begin filling the Ice Bath, which will take 4-5min. During this time the White 

Power indicator on the front UI panel should be blinking, communicating the unit is 

running its initial setup process.  

 

6.

 

Once the Ice bath has reached a suitable level (after 4-5min), the White Power indicator 

will light solid, and water can now be dispensed. 

NOTE:

 There is a 5 min delay after the 

indicator lights solid before the compressor begins to operate.  

 

7.

 

PLACE A CONTAINER IN THE DISPENSE ARE TO CATCH WATER. 

Dispense water from the 

Still and Sparkling dispense spouts, one after the other, by holding in either the small or 

large dispense button. For the Still dispense, nothing will come out for several seconds at 

first, as the lines are being filled with water. Water should begin flowing after several 

seconds. For the Sparkling dispense, the same process will occur, but there will also be 

some CO

2

 gas release during the first few seconds of dispensing as well. Continue 

dispensing until a strong stream is achieved.  

 