background image

 

WL500

 Manual 

                                                                           Page 54   Revision 4‐10‐2019 

PRE‐INSTALLATION PROCEDURES 

 

      DANGER!

 

 

ELECTRICAL SHOCK HAZARD.  

Only qualified personnel who have read and understand this entire manual should attempt to install, 
or service this unit, failure to do so could result in death or serious injury.  DO NOT plug into an 
electrical supply until specifically instructed.  

 

 

       WARNING!

  

ALWAYS SANITIZE BEFORE USE. 

 Sanitize before use to eliminate any potential microbiological contaminates.     

 

 

Materials Needed:  
 

 

Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  

 

Phillips Screwdriver.   

 

Temperature Gauge. 

 

Water Pitcher or Container to collect water from the faucet 

 

5‐gallon container or drain basin 

 

Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 

 

¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings. 

 

TDS Meter and Test Strips for measuring chlorine. ‐ Optional 

 

1/8 NPT Female Thread to ¼” Compression Fitting (Used to connect hose to drain fittings) 

 
 

1.

 

Unpack the 

Waterlogic WL500 Water Treatment System

 

and check exterior for damage. 

 

  

 

WARNING!

  

WL500 WATER TREATMENT SYSTEM IS HEAVY.

 

Use proper lifting aids and handling techniques to avoid injury.  Use assistance as single person 
lift could cause injury. Always drain before handling and transporting and handling to reduce the 
weight of the unit.  

 

   

2.

 

Remove the Retaining Screw that is located directly in front of 
the faucet nipple.  Refer to 

Figure 1

.  Removing this screw will 

allow access to the inside serviceable components (Filters and 
UV Lamp). 

 

3.

 

Open the Front Hatch Cover by lifting up and hinging outward.  
Front Hatch Cover can be removed by carefully squeezing Panel 
base and pulling over Hinge Pins. 

 

Flush Filters 
 

      

CAUTION!

  

FILTERS FLUSH REQUIRED. 

 

WL500 Water Treatment Systems

 

are not supplied with Filters.  Filters should be configured to 

optimize your system.  Filters need to be configured and specified to do the job given the local water 
conditions, usage, maintenance schedule, and placement restrictions. 

  
 
 
 
 
 
 
 
 
 

Summary of Contents for WL500 - Sparkling

Page 1: ...ne Optional 1 8 NPT Female Thread to Compression Fitting Used to connect hose to drain fittings 1 Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage WARNING WL500 WATER T...

Page 2: ...ROPER PERSONAL PROTECTIVE EQUIPMENT Always ensure proper ventilation and use proper personal protective equipment such as gloves and eye protection when using chemicals Refer to Material Safety Data S...

Page 3: ...cur within one minute and the overload high limit will require manual reset if heater is turned on with an empty Hot Tank Fill the Cold Circuit with Sanitizer 17 Wait 10 seconds for the unit to perfor...

Page 4: ...least 5 minutes UV System Functional Test WARNING ULTRAVIOLET RADIATION Protect your skin and eyes against ultraviolet rays Never look directly at an operating UV light Disconnect before removing 24 D...

Page 5: ...9 F You can monitor the Hot Tank temperature by selecting the hot button when the Temp Display is RANGING Dispense a cup of hot water to ensure the temperature odor taste is acceptable WARNING VERY HO...

Page 6: ...or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to Compressio...

Page 7: ...emove Fitting from CO2 Line 7 Attach Water Inlet Valve 8 Add 1 2 drops of Bleach into the Sparkling Tank through the Sparkling Water Level Sensor line 9 Connect Drain Water line and fitting to the Spa...

Page 8: ...ank has a drain port and is the only tank that is open to atmosphere through the vent and faucet Prior to draining the Hot Tank turn the GREEN Compressor Heater Switch off O OFF and dispense 2 liters...

Page 9: ...kling water out of the Sparkling Chamber through the faucet of the WL500 Water Treatment System into the drip tray holds 1 5 liters or other container until only CO2 gas is dispensed The Sparkling Cha...

Page 10: ...areful not to touch UV Lamp surface as oils from your hands can cause dark spots and impact the performance of the system Always wipe off lamp with alcohol wipe or equivalent if needed Ensure lamp wir...

Page 11: ...he knock out in base cabinet up to the CO2 IN bulkhead fitting on the back of the WL500 Always secure the CO2 bottle with a chain or strap to prevent tipping 6 Establish 40 60 psi 0 5 gal min potable...

Page 12: ...Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate heat Warmer environments require more clearance around th...

Page 13: ...inuous flow of water is obtained Once a continuous flow is obtained release the dispensing button Cold Tanks are now full 5 Prime the Hot Tank Holding a container under the dispensing faucet press the...

Page 14: ...generate the sparkling water by dispensing until a continuous flow of gas is obtained and release to let the pump inject cold water below 7 7 C 46 F into the chamber This provides Premium Sparkling Wa...