PRE‐INSTALLATION PROCEDURES
DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to install,
or service this unit, failure to do so could result in death or serious injury. DO NOT plug into an
electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
Phillips Screwdriver.
Temperature Gauge.
Water Pitcher or Container to collect water from the faucet
5‐gallon container or drain basin
Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings.
TDS Meter and Test Strips for measuring chlorine. ‐ Optional
1/8 NPT Female Thread to ¼” Compression Fitting (Used to connect hose to drain fittings)
1.
Unpack the
Waterlogic WL500 Water Treatment System
and check exterior for damage.
WARNING!
WL500 WATER TREATMENT SYSTEM IS HEAVY.
Use proper lifting aids and handling techniques to avoid injury. Use assistance as single person
lift could cause injury. Always drain before handling and transporting and handling to reduce the
weight of the unit.
2.
Remove the Retaining Screw that is located directly in front of
the faucet nipple. Refer to
Figure 1
. Removing this screw will
allow access to the inside serviceable components (Filters and
UV Lamp).
3.
Open the Front Hatch Cover by lifting up and hinging outward.
Front Hatch Cover can be removed by carefully squeezing Panel
base and pulling over Hinge Pins.
Flush Filters
CAUTION!
FILTERS FLUSH REQUIRED.
WL500 Water Treatment Systems
are not supplied with Filters. Filters should be configured to
optimize your system. Filters need to be configured and specified to do the job given the local water
conditions, usage, maintenance schedule, and placement restrictions.