WL400
Manual Page 74
–
Revision: 10-23-2019
9.
Water does not dispense from Unit
Possible Reason
Solution
Closed water supply valve
Open the water supply valve.
The unit is not properly
plugged into electrical outlet
Check electrical outlet connection, or for blown circuit breaker.
Green Heater and Compressor
Switch button on unit is in the
off position
Turn Green Heater / Compressor Switch on.
I = ON
15 Amp Fuse Blown
Replace the 15 Amp Fuse as needed.
Water is present in the bottom
tray, causing the leak
detection to trigger.
Remove the top cover and front panel. Tip the unit slightly to drain,
dry bottom tray completely.
Hot and Cold Solenoid
connections into the Displace
PCB are loose.
Turn power off; unplug the unit and visually inspect solenoid
connections into the Display PCB. Verify the soldering points on
connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.
Summary of Contents for WL400 Base Cabinet
Page 34: ...WL400 Manual Page 34 Revision 10 23 2019 WL400 BASE MAIN PARTS DRAWING AND PARTS LIST...
Page 42: ...WL400 Manual Page 42 Revision 10 23 2019 BASE CABINET SIDE REMOVAL...
Page 43: ...WL400 Manual Page 43 Revision 10 23 2019 BASE CABINET CONFIGURATION...
Page 45: ...WL400 Manual Page 45 Revision 10 23 2019 INSIDE LEFT SIDE CABINET CONFIGURATION...
Page 46: ...WL400 Manual Page 46 Revision 10 23 2019 INSIDE RIGHT SIDE CABINET CONFIGURATION...