13.
Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary
depending on water conditions).
14.
Place a pitcher, catch basin or other container under the faucet of the
WL400
Water Treatment
System.
15.
Flush the Hot Tank until water runs clear.
16.
Once clear water dispenses from the faucet the Hot Tank has been descaled. Always ensure unit
is performing to the customer’s satisfaction.
WARNING!
HOT WATER HAZARD. WL400 Water Treatment System produces VERY HOT
WATER up to 203°F (95°C). Water above 125°F (52°C) can cause severe burns or scalding.
Hot
water should be dispensed carefully into insulated container to avoid injury.
CAUTION
!
MUST
REPLACE HOT TANK 3-5 YEARS DEPENDING ON USAGE
. The hot tank and
its controls must be replaced a minimum of every five years to ensure efficient and dependable
operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all panels, protective
covers, and fasteners after servicing equipment. Failure to do so could result in severe personal
injury and will void the certifications and warranty of the equipment
.