background image

38

39

Waterlogic 2 Firewall Technical Manual - Issue B, May 2014

Part Description 

26

Sensor fixing Rubber

27

UV Sensor 

28

15W UV Lamp

29

Firewall UV Lamp Fixing Rubber

30

Faucet UV - Spiral Quartz

31

Spiral Quartz Spacer to Outer Quartz Sleeve

32

Faucet Firewall Housing
Firewall Faucet Bracket
Firewall Housing Bottom Cover
Firewall Top Case

33

Wire from Ballast to UV lamp

34

JG 3/8" x 1/4" Reducing Fitting

35

Firewall Top Case Cover

36

Silver Front Panel for Drip Tray insert - Firewall

37

Firewall PCB Cover

38

Firewall Display PCB (Universal H&C,C&A,CO)

39

Silicon Button Key Mat CA

Part Description 

40

Front upper insert panel

41

Button Label HC&CA

42

Drip Tray Grill

43

Drip Tray Body Charcoal with WL Logo

44

Firewall hot water faucet

45

Main PCB Fixing Bracket (FS)

46

Plastic PCB Support

47

JG Equal Elbow Connector 1/4"

48

Solenoid Valve DC24V 500mm

49

JG Equal Tee Connector 1/4"

50

15W Electronic Ballast

51

Power Transformer

52

Mini Upper Base

53

JG Equal Elbow Connector 1/4"

54

Cold Tank Assembly (4 Liters / No UV Holder)

55

JG Equal Elbow Connector 1/4"

56

Wire Condenser

Summary of Contents for WL2 Firewall

Page 1: ...Waterlogic 2 Firewall Technical Manual Issue B May 2014 WL2 Firewall Technical Manual...

Page 2: ...l operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm h...

Page 3: ...rmister and it is pre set at the factory at approximately 87 C A BI metal overload thermostat is fitted to stop the tank overheating and can be reset manually Setting the hot water temperature at 87 C...

Page 4: ...irect sunlight Placing the WL2 Firewall in direct sunlight from a window close to a radiator or in a room of high ambient temperature will affect the efficiency of the refrigeration circuit FIREWALL C...

Page 5: ...Wetted Parts Layout Cold and Ambient FILTER IN Water SOLENOID VALVE SOLENOID VALVE COLD WATER OUT FILTER DRYER COLD SENSOR COLD TANK COMPRESSOR CONDENSER FILTER IN Water SOLENOID VALVE COLD WATER OUT...

Page 6: ...Flush water approximately 10 litres through the hot tank first until the water runs clear of any carbon fines 7 Now flush water through the cold tank with approximately 10 litres of water 8 Once you a...

Page 7: ...to the machine Minimum operating pres sure for the machine to work suitably is 2 5 bar The ideal operating pressure is at 3 bar At pressures higher than 3 bar the machine will not function correctly...

Page 8: ...ou use an accurate pre viously calibrated thermometer 16 Please ensure that the cold water produced has a good taste If you detect a plastic taste then it is an indication that the machine needs to be...

Page 9: ...the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not dispense water in a stop...

Page 10: ...e The new filter can now be installed into the machine 6 Remove the UV lamp by unplugging the UV lamp connector and pulling the lamp upwards 7 Check the quartz spiral for scale build up and clean if n...

Page 11: ...grill DE SCALING Items needed to carry out the de scaling procedure Rubber gloves A container that can hold 5 liters A funnel or syringe A Phillips Cross head screwdriver De scale solution Non abrasi...

Page 12: ...tions or alterations of an unauthorised nature Adoption and use of unapproved spare parts Engagement of untrained personnel Waterlogic has a policy of constant and continual improvement and therefore...

Page 13: ...s silver technology is manufactured into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory...

Page 14: ...26 27 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Cold and Ambient 230V Models Main PCB Schematic Diagram Cold only 230V Models...

Page 15: ...28 29 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Hot and Cold 230V Models...

Page 16: ...Valve DC24V 1000mm 8 JG Equal Elbow Connector 1 4 9 JG LLD PE Tube Blue O D 1 4 10 JG Equal Elbow Connector 1 4 11 Cold Tank Assembly 4 Liters No UV Holder 12 JG Equal Elbow Connector 1 4 13 JG LLD P...

Page 17: ...15 JG Equal Elbow Connector 1 4 16 Solenoid Valve DC24V 1000mm 17 JG Equal Tee Connector 1 4 18 Solenoid Valve DC24V 1000mm 19 JG Equal Elbow Connector 1 4 20 Cushion for Solenoid Valve 21 Filter Bra...

Page 18: ...r 39 Firewall Display PCB Universal H C C A CO 40 Silicon Button Key Mat CA 41 Firewall Front Upper Insert Panel 42 Button Label HC CA 43 Drip Tray Grill 44 Drip Tray Body Charcoal 45 Firewall Hot Wat...

Page 19: ...r Fuse 6 Socket for Plug Connection 7 Gasket for Power Socket 8 Silver Side Panel Left 9 JG Bulkhead Connector Union 1 4 1 4 10 Plastic Cap for 1 4 Bulkhead Fitting 11 Compressor 12 Down Base 13 Bolt...

Page 20: ...lver Front Panel for Drip Tray insert Firewall 37 Firewall PCB Cover 38 Firewall Display PCB Universal H C C A CO 39 Silicon Button Key Mat CA N Part Description 40 Front upper insert panel 41 Button...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...

Reviews: