Waterlogic 2 Firewall Technical Manual - Issue B, May 2014

Maintenance and Servicing

6 MONTH SERVICE PROCEDURE

This procedure should only be carried out by persons trained by Waterlogic 

International or their approved distributors.

The following instructions cover models that can include Hot, Cold, Ambient.

• Every six months the filters and UV lamp must be changed. 

• The Firewall quartz spiral must be removed, checked and cleaned every six

months if needed.

• A WL2 Firewall with a hot water option may require having any calcium build 

up inside the hot tank removed, depending on local water conditions.

• 

No paperwork or cleaning records should ever be stored inside

the WL2 Firewall.

1. 

Isolate the power to the WL2 Firewall by turning off the red switch and removing 

the power cord at the rear of the WL2 Firewall.

2. 

To access the filters, undo the screws and release the clips located in front 

of the lower front panel and remove the panel to gain access to the interior of 

machine. To access the filters on a mini machine just remove the top cover. This is 

a high voltage area and the machine should be isolated from the power supply.

3. 

When a valved twist filter head is installed there is no need to turn off the water 

supply; the water is automatically isolated when you remove the filter.

4. 

To remove the Waterlogic filters, twist the filter anti-clockwise.

5. 

The new filter will require flushing prior to being re-fitted in the WL2 Firewall. 

To do this connect a water feed directly into the inlet side of the filter and attach 

another length of pipe to the outlet side and direct this into a bucket/large 

container or drain, then flush through 10 litres of water to ensure that any loose 

carbon fines are fully removed from the filter to avoid any damage being caused 

to the machine. The new filter can now be installed into the machine.

6. 

Remove the UV lamp by unplugging the UV lamp connector and pulling the 

lamp upwards.

7. 

Check the quartz spiral for scale build up and clean if necessary.

8. 

Fit the quartz spiral back into the Firewall Chamber taking great care at this 

stage not to crack the quartz.

9. 

Replace the UV lamp assembly and re-connect it. Do not touch the UV lamp 

with bare hands.

10. 

Inspect the electrical and water connections of the machine.

11. 

Check the air gap around the machine to ensure it is not blocked.

12. 

Turn on the red switch, on the back of the machine.

13. 

Check that the UV lamp is alight by observing a blue glow from the top of the 

UV cap. Do not remove the lamp from the holder whilst ignited and do not look 

into an ignited UV light.

14. 

Close the front of the machine and the top of the machine by fitting the panels 

back to their original position.

15. 

Flush through 5 litres of hot and cold water to ensure the water is running clear 

of any carbon fines and that the taste of the water is clean and to the customers 

satisfaction. If you are not happy with the quality of the water continue to flush an 

additional 2-5 litres of water until you are satisfied with the taste.

16. 

Turn on the heater and compressor switch and allow the machine to cool and 

heat the water.

17. 

Clean the outside of the machine with a non-abrasive anti-bacterial wipe or 

cloth.

18. 

Taste the water one final time and check the machine is cooling and heating 

the water.

SANITISING

Items needed to carry out the sanitization procedure:

• 

An empty Waterlogic in-line filter housing.

• 

Rubber gloves.

• 

Antibacterial wipes or spray.

• 

Suitable test strips to work with your sanitisation fluid.

• 

A Phillips screwdriver.

• 

Sanitisation fluid.

• 

A 5 litre container.

1. 

Put on the rubber gloves to minimise the chance of any contamination to the 

machine whilst the sanitisation procedure is being carried out.

2. 

Turn off the water supply to the machine and release the internal pressure by 

Summary of Contents for WL2 Firewall

Page 1: ...Waterlogic 2 Firewall Technical Manual Issue B May 2014 WL2 Firewall Technical Manual...

Page 2: ...l operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm h...

Page 3: ...rmister and it is pre set at the factory at approximately 87 C A BI metal overload thermostat is fitted to stop the tank overheating and can be reset manually Setting the hot water temperature at 87 C...

Page 4: ...irect sunlight Placing the WL2 Firewall in direct sunlight from a window close to a radiator or in a room of high ambient temperature will affect the efficiency of the refrigeration circuit FIREWALL C...

Page 5: ...Wetted Parts Layout Cold and Ambient FILTER IN Water SOLENOID VALVE SOLENOID VALVE COLD WATER OUT FILTER DRYER COLD SENSOR COLD TANK COMPRESSOR CONDENSER FILTER IN Water SOLENOID VALVE COLD WATER OUT...

Page 6: ...Flush water approximately 10 litres through the hot tank first until the water runs clear of any carbon fines 7 Now flush water through the cold tank with approximately 10 litres of water 8 Once you a...

Page 7: ...to the machine Minimum operating pres sure for the machine to work suitably is 2 5 bar The ideal operating pressure is at 3 bar At pressures higher than 3 bar the machine will not function correctly...

Page 8: ...ou use an accurate pre viously calibrated thermometer 16 Please ensure that the cold water produced has a good taste If you detect a plastic taste then it is an indication that the machine needs to be...

Page 9: ...the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not dispense water in a stop...

Page 10: ...e The new filter can now be installed into the machine 6 Remove the UV lamp by unplugging the UV lamp connector and pulling the lamp upwards 7 Check the quartz spiral for scale build up and clean if n...

Page 11: ...grill DE SCALING Items needed to carry out the de scaling procedure Rubber gloves A container that can hold 5 liters A funnel or syringe A Phillips Cross head screwdriver De scale solution Non abrasi...

Page 12: ...tions or alterations of an unauthorised nature Adoption and use of unapproved spare parts Engagement of untrained personnel Waterlogic has a policy of constant and continual improvement and therefore...

Page 13: ...s silver technology is manufactured into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory...

Page 14: ...26 27 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Cold and Ambient 230V Models Main PCB Schematic Diagram Cold only 230V Models...

Page 15: ...28 29 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Hot and Cold 230V Models...

Page 16: ...Valve DC24V 1000mm 8 JG Equal Elbow Connector 1 4 9 JG LLD PE Tube Blue O D 1 4 10 JG Equal Elbow Connector 1 4 11 Cold Tank Assembly 4 Liters No UV Holder 12 JG Equal Elbow Connector 1 4 13 JG LLD P...

Page 17: ...15 JG Equal Elbow Connector 1 4 16 Solenoid Valve DC24V 1000mm 17 JG Equal Tee Connector 1 4 18 Solenoid Valve DC24V 1000mm 19 JG Equal Elbow Connector 1 4 20 Cushion for Solenoid Valve 21 Filter Bra...

Page 18: ...r 39 Firewall Display PCB Universal H C C A CO 40 Silicon Button Key Mat CA 41 Firewall Front Upper Insert Panel 42 Button Label HC CA 43 Drip Tray Grill 44 Drip Tray Body Charcoal 45 Firewall Hot Wat...

Page 19: ...r Fuse 6 Socket for Plug Connection 7 Gasket for Power Socket 8 Silver Side Panel Left 9 JG Bulkhead Connector Union 1 4 1 4 10 Plastic Cap for 1 4 Bulkhead Fitting 11 Compressor 12 Down Base 13 Bolt...

Page 20: ...lver Front Panel for Drip Tray insert Firewall 37 Firewall PCB Cover 38 Firewall Display PCB Universal H C C A CO 39 Silicon Button Key Mat CA N Part Description 40 Front upper insert panel 41 Button...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...

Reviews: