background image

20

21

Waterlogic 2 Firewall Technical Manual - Issue B, May 2014

pushing the cold button momentarily. Then disconnect the water feed pipe from 

the bulkhead at the rear of the machine. 

3. 

Measure 50ml of sanitising fluid into the empty filter housing and securely 

fasten the filter head.

4. 

Insert the water feed pipe into the inlet fitting of the inline filter housing 

containing sanitisation fluid. Attach a length of ¼” water pipe into the outlet fitting 

and insert the other end of the pipe into the bulkhead at the rear of the machine.

5. 

Remove the cartridge from the filter installed inside of the machine to avoid the 

mixing of sanitisation fluid and the active carbon, reattach the filter head securely.

6. 

The water supply to machine can now be turned on.

7. 

Dispense cold water until the sanitisation fluid leaves the faucet, by pressing the 

correct button for enough time until the colour of the test strip is changed by the 

water. Do not let any sanitisation fluid enter the hot tank.

8. 

Leave the sanitisation fluid inside the machine for a minimum of 20 minutes, 

when this time has been reached, flush water through the machine until there is 

no sanitisation fluid left inside. Replace the cartridge into the internal filter and 

remove the empty filter housing from the back of the machine, connect the water 

feed pipe directly into the bulkhead and turn water supply on.

9. 

Inspect faucet nipple and replace if cracked, damaged or if there is a calcium 

build up.

10. 

Isolate the power to the machine, then remove the quartz spiral by undoing 

the three screws on the top of the Firewall housing, disconnecting the UV sensor 

and water pipe, and removing the UV lamp. Inspect the spiral for any damage 

or calcium build up, if there is a large amount of calcium remove and replace the 

spiral and send it away to be treated by an ultrasonic bath.

11. 

Using the antibacterial wipes or spray, sufficiently clean the exterior panels of 

the machine, including the removal and cleaning of the WL2 drip tray and grill.

DE-SCALING

Items needed to carry out the de-scaling procedure:

• Rubber gloves.
• A container that can hold 5 liters.
• A funnel or syringe.
• A Phillips / Cross head screwdriver.
• De-scale solution.
• Non-abrasive antibacterial wipes or cloth.

1. 

Put on the rubber gloves to minimise the chance of any contamination to the 

machine and to protect yourself whilst the servicing procedure is being carried 

out.

2. 

Dispense 200ml of hot water from the machine and check that the water is hot, 

if the water is not hot allow time for the machine to heat the water up.

3. 

Switch off the power switche at the rear of the machine and completely remove 

the power lead from the unit.

4. 

Disconnect the silicone tubing from the top of the hot tank.

5. 

Remove the hot water drainage valve and drain about 200ml of water.

6. 

Add the de-scale solution into a container and mix it with no more than 200ml 

of water as per the manufactures instructions.

7. 

If you are using a syringe then draw the de-scale solution into the syringe and 

add the solution into the hot tank. If you are using a funnel insert the end of the 

funnel into the open hot tank outlet and pour the de-scale solution into the hot 

tank, this should be done slowly with both methods as adding the solution to 

quickly can result in the tank overflowing.

8. 

Reattach the silicone tubing onto the hot tank outlet and secure it with the 

fastening clamp.

9. 

Turn on the incoming water supply at the isolation point.

10. 

Reconnect the power lead and insert it into the rear of the machine. Turn on 

the power switches at the rear of the machine.

11. 

Leave the de-scale solution to stand in the hot tank for 15 minutes. Once this 

time has passed select the hot water icon and then the dispense button and flush 

8-10 liters of hot water, through the machine. Taste test the water, if there is any 

hint of taste to the water flush a further 10 liters of hot water.

12. 

Clean the outside of the machine with the non-abrasive anti-bacterial wipe or 

cloth.

13. 

Taste the water one final time, if you detect any hint of taste, flush a further 10 

liters of water.
 

14. 

Check the machine is heating and cooling the water by dispensing some hot 

and cold water and checking the temperatures.

Summary of Contents for WL2 Firewall

Page 1: ...Waterlogic 2 Firewall Technical Manual Issue B May 2014 WL2 Firewall Technical Manual...

Page 2: ...l operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm h...

Page 3: ...rmister and it is pre set at the factory at approximately 87 C A BI metal overload thermostat is fitted to stop the tank overheating and can be reset manually Setting the hot water temperature at 87 C...

Page 4: ...irect sunlight Placing the WL2 Firewall in direct sunlight from a window close to a radiator or in a room of high ambient temperature will affect the efficiency of the refrigeration circuit FIREWALL C...

Page 5: ...Wetted Parts Layout Cold and Ambient FILTER IN Water SOLENOID VALVE SOLENOID VALVE COLD WATER OUT FILTER DRYER COLD SENSOR COLD TANK COMPRESSOR CONDENSER FILTER IN Water SOLENOID VALVE COLD WATER OUT...

Page 6: ...Flush water approximately 10 litres through the hot tank first until the water runs clear of any carbon fines 7 Now flush water through the cold tank with approximately 10 litres of water 8 Once you a...

Page 7: ...to the machine Minimum operating pres sure for the machine to work suitably is 2 5 bar The ideal operating pressure is at 3 bar At pressures higher than 3 bar the machine will not function correctly...

Page 8: ...ou use an accurate pre viously calibrated thermometer 16 Please ensure that the cold water produced has a good taste If you detect a plastic taste then it is an indication that the machine needs to be...

Page 9: ...the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not dispense water in a stop...

Page 10: ...e The new filter can now be installed into the machine 6 Remove the UV lamp by unplugging the UV lamp connector and pulling the lamp upwards 7 Check the quartz spiral for scale build up and clean if n...

Page 11: ...grill DE SCALING Items needed to carry out the de scaling procedure Rubber gloves A container that can hold 5 liters A funnel or syringe A Phillips Cross head screwdriver De scale solution Non abrasi...

Page 12: ...tions or alterations of an unauthorised nature Adoption and use of unapproved spare parts Engagement of untrained personnel Waterlogic has a policy of constant and continual improvement and therefore...

Page 13: ...s silver technology is manufactured into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory...

Page 14: ...26 27 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Cold and Ambient 230V Models Main PCB Schematic Diagram Cold only 230V Models...

Page 15: ...28 29 Waterlogic 2 Firewall Technical Manual Issue B May 2014 Main PCB Schematic Diagram Hot and Cold 230V Models...

Page 16: ...Valve DC24V 1000mm 8 JG Equal Elbow Connector 1 4 9 JG LLD PE Tube Blue O D 1 4 10 JG Equal Elbow Connector 1 4 11 Cold Tank Assembly 4 Liters No UV Holder 12 JG Equal Elbow Connector 1 4 13 JG LLD P...

Page 17: ...15 JG Equal Elbow Connector 1 4 16 Solenoid Valve DC24V 1000mm 17 JG Equal Tee Connector 1 4 18 Solenoid Valve DC24V 1000mm 19 JG Equal Elbow Connector 1 4 20 Cushion for Solenoid Valve 21 Filter Bra...

Page 18: ...r 39 Firewall Display PCB Universal H C C A CO 40 Silicon Button Key Mat CA 41 Firewall Front Upper Insert Panel 42 Button Label HC CA 43 Drip Tray Grill 44 Drip Tray Body Charcoal 45 Firewall Hot Wat...

Page 19: ...r Fuse 6 Socket for Plug Connection 7 Gasket for Power Socket 8 Silver Side Panel Left 9 JG Bulkhead Connector Union 1 4 1 4 10 Plastic Cap for 1 4 Bulkhead Fitting 11 Compressor 12 Down Base 13 Bolt...

Page 20: ...lver Front Panel for Drip Tray insert Firewall 37 Firewall PCB Cover 38 Firewall Display PCB Universal H C C A CO 39 Silicon Button Key Mat CA N Part Description 40 Front upper insert panel 41 Button...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...