background image

 

WL15

 Manual 

                                                      Page 33 – Revision:  4-15-22 

 

WL15 INSTALLATION, FILTER FLUSHING, AND SANITIZING PROCEDURES 

 

        DANGER!

 

 

ELECTRICAL SHOCK HAZARD.  

Only qualified personnel who have read and understand this entire manual should      
attempt to install, or service this 

WL15 Water Dispenser

, failure to do so could result in 

death or serious injury.  DO NOT plug into an electrical supply until specifically 
instructed. Always unplug (isolate from power supply) to prevent electrical shock except 
where electrical tests are specified.  

       WARNING!

  

ALWAYS SANITIZE BEFORE USE. 

Sanitize before use to eliminate any potential microbiological contaminates.      

CAUTION!

  

DRIP TRAY DRAIN.

  

The 

WL15 Water Dispenser

 has a drip tray that is NOT pre-plumbed to any drain or 

collection device and must be periodically emptied.  

WARNING!

  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

  

Always ensure proper ventilation and use proper personal protective equipment such as 
gloves and eye protection when using chemicals.  Refer to Material Safety Data Sheet for 
specific requirements of each chemical product. Take all necessary precautions to 
prevent sanitizer from contacting eyes, clothing, and any other surfaces in could damage 
(carpets).   

CAUTION!

  

HOT CIRCUIT IS NOT SANITIZED.  

 

Water in the hot circuit is not sanitary until the temperature exceeds 77°C (171°F) for at 
least 5 minutes. 

CAUTION!

  

INDOOR USE ONLY.

 

Never expose to direct sunlight, heat sources, or ambient air temperature above 38°C 
(100°F) or below 2°C (35°F).  Install indoors and keep unit away from excessive humidity.  
Never expose to freezing temperatures.  Ensure there is adequate clearance around the 
unit to allow refrigeration system condenser to dissipate heat.  Warmer environments 
require more clearance around the unit.  Minimum clearance around all surfaces of the 
machine is 2-inches.  Installs where the ambient temperature exceeds 80°F, require a 
minimum of 4-inches clearance for proper heat dissipation and efficient operation. 

CAUTION!

  

USE UV STABILIZED SUPPLY LINES.

 

Feed the unit with a potable ambient or cold-water supply only.  Feed water over 100° F 
(37°C) can damage the treatment components.  Water block devices and external leak 
detectors are strongly recommended. Locate the unit as close to the water supply and 
the electrical connections as possible.  

 

 

 
 
 
 
 
 

Summary of Contents for WL15

Page 1: ...chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets CAUTION HOT CIRCUIT IS NOT SANITIZED Water in the hot...

Page 2: ...ect fittings Sanitizing Cartridge Food Coloring optional 1 Unpack the Waterlogic WL15 Water Dispenser and check exterior for damage 2 Identify the ports on the back of the machine All ports are clearl...

Page 3: ...ion between the UV lamp and the PCB 8 Turn on the Soda switch on the back panel of the unit I ON to engage the carbonator pump and begin filling the carbonator tank The carbonator pump should be easil...

Page 4: ...pensed Small black flakes in the water are normal and is the purpose of this flushing operation This is only loose carbon from the filters Fill the Hot Tank 2 Using the control panel dispense hot wate...

Page 5: ...he center of the drain port which will allow the lower cap to be turned 180 degrees and removed Have a bucket or pitcher ready to catch the water as it drains out of the port 4 Once the water has comp...

Page 6: ...he upper panel aside 2 With the upper panel removed locate the UV module The UV bulb is inserted from the top with the wires running out and to the PCB Locate the plastic connector closest to the bulb...

Page 7: ...E POWER SOURCE 2 Locate the hot tank Then locate the high limit overload thermostat on the tank From this perspective it will be difficult to see The photos below illustrate what to look for 3 Press t...

Page 8: ...loves and eye protection when using chemicals Refer to Material Safety Data Sheet for specific requirements of each chemical product Take all necessary precautions to prevent sanitizer from contacting...

Page 9: ...the draining procedure for instruction on how to do this 5 Allow descaling solution to remain in the Hot Tank for 15 20 minutes 6 Reconnect the tube from the faucet to the center port of the Hot Tank...

Reviews: