WL100
Operating,
Installation,
and
Service
Manual
Page
27
Revision:
5
‐
20
‐
2016
RESETTING
THE
HOT
TANK
OVERLOAD
OR
HIGH
LIMIT
SAFETY
1.
Red
Compressor/Heater
Switch
must
be
in
the
O=OFF
position
2.
Unplug
the
Power
Cord
from
rear
of
unit.
3.
Remove
the
Lower
Front
Panel
of
unit
by
removing
the
Phillips
head
screws
underneath
the
Lower
Front
Panel.
4.
Locate
the
Protective
Metal
Box
on
the
rear
of
the
hot
tank.
As
you
look
through
the
condenser
coils
on
the
rear
of
the
unit,
you
will
see
the
hot
tank
located
on
the
right
hand
side.
5.
From
the
front
of
the
Water
Treatment
System,
reach
up
behind
the
hot
tank
and
take
hold
of
the
protective
metal
box
covering
the
thermostat
and
overload
on
the
Hot
Tank.
There
are
nuts
that
secure
the
Protective
Metal
Box
to
the
Hot
Tank,
are
loose
enough
to
allow
you
to
remove
the
Protective
Metal
Box.
If
the
nuts
on
the
metal
box
are
too
tight,
loosen
the
nuts
securing
the
Hot
Tank
to
the
upper
base
of
the
WL100
Water
Treatment
System
unit
and
lower
the
Hot
Tank
so
you
can
remove
the
Protective
Metal
Box.