WL100
Operating,
Installation,
and
Service
Manual
Page
52
Revision:
5
‐
20
‐
2016
Red
Power
Switch
is
lit
but
the
Red
LED
on
the
Front
is
not
lit
Possible
Reason
Solution
Bad
Transformer
Replace
Transformer
Black
Power
Connector
to
the
PCB
is
not
properly
connected
Properly
connect.
Bad
Front
PCB
(Part
Number
EN
‐
6130
–
WLCP
PN
20
‐
0040)
Replace
Front
PCB
Bad
Energy
Saver
PCB
(Part
Number
EN
‐
6131
–
WLCP
PN
20
‐
0075
Replace
Energy
Saver
PCB
Defective
Red
Heater
/
Compressor
Switch
Replace
Red
Heater
/
Compressor
Switch
Compressor
Runs
But
Does
Not
Chill
Possible
Reason
Solution
Condenser
is
dirty
Clean
the
condensing
coil
of
any
obstructions
or
dust.
Reduction
of
airflow
into
unit.
Make
sure
unit
is
not
under
minimum
ventilation
requirements
(2
to
4
inches).
Compressor
is
running
very
hot.
Low
or
lost
refrigerant.
Refrigerant
recharge
required.