![WaterLogic WL100 Operating, Installation And Service Manual Download Page 17](http://html2.mh-extra.com/html/waterlogic/wl100/wl100_operating-installation-and-service-manual_3637595017.webp)
WL100
Operating,
Installation,
and
Service
Manual
Page
17
Revision:
5
‐
20
‐
2016
WL100
COUNTER
TOP
DRAINING
INSTRUCTIONS
Draining
Notes
Drain
the
WL100
Water
Treatment
System
for
transportation.
WARNING!
STORE
UNIT
EMPTY.
ALWAYS
SANITIZE
BEFORE
REUSE.
The
unit
must
be
completely
drained
and
sealed
before
storing
to
avoid
stagnation
and
reduce
microbial
growth).
Prior
to
draining
the
Hot
Tank,
turn
off
the
Red
Heater
and
Compressor
Switch
–
O=OFF
,
and
dispense
2
Liters
(½
Gallon)
of
hot
water
from
the
WL100
Water
Treatment
System
.
As
hot
water
is
dispensed
from
the
faucet
of
the
unit,
colder
water
will
be
introduced
into
the
Hot
Tank.
Since
the
Red
Heater
and
Compressor
Switch
is
turned
off,
the
Heater
will
not
energize
and
heat
the
incoming
tap
water.
Following
this
precaution
prevents
exposing
personnel
and
equipment
(drains,
catch
basin,
etc.)
from
scalding
hot
water.
Disable
Cold
and
Hot
Tanks
1.
Turn
off
the
Red
Heater
and
Compressor
Switch
to
disable
the
heater
and
compressor.
Red
Compressor/Heater
Switch
must
be
in
the
O=OFF
position
2.
Dispense
2
liters
(½
Gallon)
of
water
through
the
Hot
Tank
to
cool
the
water
temperature
in
the
Hot
Tank
and
avoid
burns.
WARNING!
HOT
WATER.
Unit
produces
Hot
Water
up
to
87
o
C
(189
o
F).
Water
above
52
o
C
(125
o
F)
can
cause
severe
burns
or
scalding.
Hot
water
should
be
dispensed
carefully
into
insulated
container
to
avoid
injury.
Turn
off
Water
Supply
and
Bleed
Water
Pressure
3.
Isolate
WL100
Water
Treatment
System
from
feed
water
by
turning
off
the
supply.
4.
Dispense
cold
still
water
to
relieve
any
pressure
built
up
in
the
system.
Drain
the
Cold
Water
Tank
and
Circuit
5.
Remove
Top
Cover.