CUBE
Manual
Page 29 – Revision 10‐8‐2018
UV LAMP REPLACEMENT
1.
Remove the UV Lamp Protective Cover from the front
right‐hand side of the
CUBE
by removing the fixing
screw and lifting the cover up
2.
Disconnect the UV Lamp Connector by pressing in the
clip on the side of the machine.
Pull the connector towards the front of the machine.
3.
Firmly pull the old UV Lamp up and out of the
CUBE
.
Do not pull the lamp out an angle as it may break or
damage the internal parts of the
CUBE
.
4.
Insert the new UV Lamp while holding the white end
caps only.
Insert the UV Lamp, ensuring you have pushed it all
the way down until it cannot go any further.
Reconnect the UV lamp Connector, making sure the
connectors are lined up correctly as they will only fit
when correctly aligned.
5.
Reinstall the UV Lamp Protective Cover and Secure it
in place with the fixing screw.
6.
Install the Top Cover onto the machine by placing
cover into position. Ensure the two fixing logs at the
front are lined up with the grooves, then pulling the
cover firmly towards yourself until it clicks into place.