CUBE
Manual
Page 22 – Revision 10‐8‐2018
16.
Reconnect the power lead and insert it into the rear of the machine.
Turn ON the Red Power Switch.
I=ON
17.
Place a container under the dispense area. Select the Hot
Water Icon and then the Dispense button.
Dispense 2 quarts of water.
18.
Turn on Green Heater/Compressor Switch at rear of machine.
I =
ON
19.
Leave the descale solution fluid to stand in the Hot Tank for 20 minutes.
After 20 minutes, select the Hot Water Icon, select the Dispense button and flush 3 gallons
of Hot water through the
CUBE
.
20.
Turn off the water supply at the isolation point.
21.
Select the Cold‐Water Icon, then the Dispense Button until no
water dispenses from the
CUBE
.
22.
Switch Off the Red Power and Green Heater/Compressor Switch at the
rear of the machine.
O=OFF
23.
Remove the Power Lead from the unit.
24.
Insert your finger into the round hole of the lever,
and pull the lever up to the vertical position.
NOTE:
Make sure the front Filter with descaling
solutions is the one removed.