Electrical work
05.06.2015
43 / 80
Copyright
2013 by: WATERKOTTE GmbH. Subject to changes.
10.1
Electrical connection outdoor unit
On the outdoor unit, the electrical terminal strip is located behind the ser-
vice panel. Clamp the cables in such a way that they do not contact the
centre of the service panel or the gas valve.
Open service panel:
Loosen 3 screws, push service panel down and remove.
Follow the wiring diagram!
Before carrying out electrical work:
Make sure to install circuit breakers. Otherwise risk of electric shock.
For the power lines, use standard cables of sufficient capacity. Other-
wise there is a risk of short circuits, overheating or fire.
When installing power lines, do not apply tension to the cables. Loos-
ened connections pose a risk of cables slipping from terminals or
breaking; this can result in overheating or fire.
Figure 19: Electrical terminal strip outdoor unit
Connections:
Feed line connection compressor-terminal:
L1, L2, L3, N, PE (400 V)
L, N, PE (230 V) – (not shown)
Bus connection (indoor / outdoor unit)
S1, S2, S3 and PE (230 V and 400 V)
Line connection to be performed as required by country and type.
Neutral conductor must be connected too.
Failure to observe: results in destruction of circuit board on outdoor unit.