background image

13

How to Flush the Filter After Replacement:

For the CF filter:

 Turn on the RO faucet to flush for 5 minutes;

For the MRO membrane filter:

 Turn on the RO faucet to flush for 30 minutes.

NOTE:

 

Turn on the faucet to flush for 30 minutes if replacing the CF filter and 

MRO membrane filter at the same time.

Section 4: Malfunction Display

Overworked Reminder:

When the system continuously makes water for more than 30 minutes, the 

overworked reminder will be executed and the buzzer will beep for 3 minutes. The 

system stops making water when working for over 33 minutes, and the filtering 

indicator and power indicator are off. Meanwhile, the CF and MRO filter life 

indicators flash red. The system needs to be powered on again to recover itself.

Starting and Stopping Frequently Reminder:

The RO system will perform a starting and stopping frequently reminder when the 

booster pump is frequently started and stopped in 20 minutes. The system will 

stop making water, while the filtering indicator and power indicator are off and the 

CF and MRO filter life indicators flash purple. The system needs to be powered on 

again to recover itself.

 

If you do not use the machine for a long time (more than 1 week), it is 

recommended to turn on the faucet to flush for a while before using it again;

 

Please replace the filter regularly according to the filter life indicator;

NOTE:

 

While the testing was performed under standard laboratory conditions, 

actual performance may vary depending on the source water quality and 

water usage. In case of a premature blockage and failure of the filters, it’s 

recommended to replace the filter in accordance with actual usage. 

 

Clean the system with clear water. Do not spray the water directly onto the filter. 

Do not use steel wool, an abrasive cleaner or a corrosive liquid such as gasoline 

or acetone;

 

When cleaning, do not pour other liquids into the filter or you risk damaging the 

filter system;

 

Keep the waste water pipe unobstructed to avoid damage to the filter or internal 

components;

 

When the drainpipe is blocked, do not use the system (please turn off the 

power) to avoid the waste water from soaking the floor;

 

Check the system and water pipe fittings regularly for water leakage to avoid 

any property damage;

 

Regularly check whether the power supply and wires are damaged or loose to 

avoid major accidents caused by electric leakage.

System Maintenance

Summary of Contents for G2 Series

Page 1: ......

Page 2: ......

Page 3: ...onditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any Changes or modification...

Page 4: ......

Page 5: ...he RO Faucet 6 Step 3 Install the Drain Saddle 7 Step 4 Position the RO System Housing 7 Step 5 Connect Tubing 8 Step 6 Start up the System 9 Owner s Manual Display and Operation 10 Section 1 Working...

Page 6: ...or quick installation Specifications To achieve the optimal performance it is highly recommended to use the system within the operational parameters Model RO System Size L W H Feed Water Pressure Feed...

Page 7: ...O System Feed Water Adapter 3 8 and 1 2 White 1 4 PE Tubing Drain Saddle 1 4 Teflon Tape Red 1 4 PE Tubing White 3 8 PE Tubing Lock Clip X 1 Set RO Faucet X 1 Set X 1 Set X 1 X 1 Set X 59 X 59 X 59 X...

Page 8: ...installation Power Indicator Filtering Indicator MRO Filter Life Indicator CF Filter Life Indicator Front Top Multiple Reverse Osmosis Membrane Filter MRO RO Faucet Filtered Water Tubing Power Kitchen...

Page 9: ...g off To disconnect Remove the blue lock clip from the fitting Use your thumb and index finger to press down on the lock sleeve Use your other hand to pull out the tube from the fitting Figure 2 NOTE...

Page 10: ...e into Your Sink or Countertop Optional NOTE Please confirm if there is an existing hole available to install the RO faucet If not please drill a hole in accordance with the following steps It s highl...

Page 11: ...he faucet stem into the hole on the countertop 3 Under the sink slip on other parts in the order shown in the picture Figure 5 4 Insert the quick connect fitting onto the faucet stem fully and firmly...

Page 12: ...to secure the connection Figure 8 NOTE In some areas the WASTE water tubing needs to be connected to the drainpipe through the air gap Consumers need to purchase additional air gap accessories Figure...

Page 13: ...ct the filtered water tubing from the RO faucet to the F filtered water port NOTE Make sure it is fully inserted until you reach the mark on the tubing Quick connect Fitting on RO Faucet Filtered Wate...

Page 14: ...ure it out NOTE The system will beep The filter life indicators will flash blue purple and red in turn and then stay on blue for 3 seconds Figure 10 3 Turn on the faucet to let water run for 30 minute...

Page 15: ...ring indicator is off when the system stops making water and the rest of the indicators are still on Figure 12 Section 2 Filter Life Reminder Pre sediment and Carbon Block Filter CF Multiple Reverse O...

Page 16: ...ace Filters The filters could be replaced directly without cutting off the power and water and there will be no water and electric leakage 1 Twist the filter that needs to be replaced counterclockwise...

Page 17: ...need to choose if only one filter expired The filter life indicator will flash when it is selected 3 Press the reset indicator for 5 seconds again The reset is completed when you hear a beep The filt...

Page 18: ...to be powered on again to recover itself If you do not use the machine for a long time more than 1 week it is recommended to turn on the faucet to flush for a while before using it again Please replac...

Page 19: ...o ensure all tubing is installed correctly and completely b Filter expires Check the filter life indicators to confirm which filter needs to be replaced and replace it immediately c Low water temperat...

Page 20: ...cked and power on the system again Loud Sound from the RO System The sound will not exceed 55 DB which makes no difference to everyday life 55 DB is tested under standard laboratory conditions and the...

Page 21: ...tions or standards is provided solely for your convenience The quality of water supplies may vary seasonably or over a period of time Your water usage may vary as well The manufacturer shall assume no...

Page 22: ...a 30 day money back guarantee a 1 year manufacturer warranty and lifetime tech support for all our products Please be sure to fill in the order information upon registration of your system For any que...

Page 23: ......

Page 24: ......

Reviews: