![Waterdrop G2 Series Instruction Manual Download Page 20](http://html1.mh-extra.com/html/waterdrop/g2-series/g2-series_instruction-manual_3602032020.webp)
15
•
Booster Pump Overworked Reminder
Buzzer keeps beeping for 3 minutes and then the filter life indicators on the front
panel flash red.
a.
Continuously dispensing water for more than 30 minutes: Power on the system
again to recover.
b. There is a leak at the tubing connection between the system and RO faucet:
Turn off the power. Check the tubing connection, make sure the tubing is
inserted into the quick-connect fitting properly and firmly, and power on the
system again.
•
Booster Pump Starting and Stopping Frequently Reminder
Buzzer beeps 5 times and then the filter life indicators on the front panel flash
purple. There is an internal pressure imbalance: Disconnect the power. Turn on or
turn off the RO faucet completely, remove all tubing crimps. Make sure the faucet is
not blocked and power on the system again.
•
Loud Sound from the RO System
The sound will not exceed 55 DB, which makes no difference to everyday life (55
DB is tested under standard laboratory conditions, and the feed water pressure
is between 14.5 PSI and 87 PSI). A loud sound may be caused by the following
reasons:
a. The system is not positioned in a flat area. Make sure the system is placed
smoothly without shaking.
b. The system is placed against the cabinet. Do not place the system against the
cabinet. The system may vibrate when it works.
c. The water pressure is instable. Check and confirm the water pressure is
between 14.5 PSI and 87 PSI. The sound will decrease when the water
pressure becomes stable.
•
Filtered Water from the RO Faucet Tastes Like Tap Water
a.
Incorrect tubing installation: Make sure the waste water tubing is not connected
with the RO faucet.
b. Filter expires: Check the filter life indicators to confirm which filter needs to be
replaced and replace it immediately.