7
1. Set time of day:
PROGRAMMING PROCEDURES:
NOTE:
The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated
after the hardness is entered .
STEP 1
– Press
next
and
+
simultaneously for 3 seconds .
STEP 2
–
HARDNESS:
Set the amount of hardness in grains per gallon (default 20)
using the
+
or
—
buttons . The allowable range is from 1 to 150 in 1 grain
increments .
NOTE:
If a resin media is used in the softener, increase the grains per
gallon if soluble iron is present (1 ppm = 4 gpg) . This display will show
“–nA– (not available)” if “FILTER” is selected or if “AUTO” is not factory set .
Press
next
to go to step 3 .
Press
regen
if you want to exit .
STEP 3
–
DAYS BETWEEN REGENERATION (DAY OVERRIDE):
The manufacturer
has factory set OFF as the default . When set to “OFF”, regeneration initiation
is based solely on gallons used . If any number is set (allowable range from
1 to 28), a regeneration initiation will be called for on that day even if a
sufficient number of gallons were not used to call for a regeneration .
Set Day Override using
+
or
—
buttons (6 is recommended):
• set number of days between regeneration (1 to 28); or
• set to “OFF”
Press
next
to go to step 4 . Press
regen
to return to the previous step .
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends . If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset .
STEP 1
– Press
set
clock
.
STEP 2
–
CURRENT TIME (HOUR):
Set the hour of the day using
+
or
—
buttons . AM/PM toggles after 12 .
Press
next
to go to step 3 .
STEP 3
–
CURRENT TIME (MINUTES):
Set the minutes using
+
or
—
buttons . If it is desired to back up to the
previous step press
regen
button once . Press
next
to go to step 4 .
STEP 4
–
CURRENT DAY:
Set the day of the week using
+
or
—
buttons . Pressing
next
will exit
set
clock
and
return to the general operating display (page 9) .
TIME
HOUR
SET
2:00
AM
2
TIME
MINUTES
SET
2:10
AM
3
CURRENT DAY
SET
MON
4
1
1
WATER HARDNESS
SET
20
GR
2
DAYS BETWEEN REGEN
SET
OFF