TOTALCARE TWIN SPECIFICATIONS:
31
CYCLE TIMES
(in minutes)
1
All TotalCare water conditioners are pre-factory set at medium salting . Note: influent waters must be at least 3 GPG hardness and 80 TDS .
A calcite or corosex unit may be needed for correct operation .
2
Combined iron and manganese removal varies depending on the form of iron, manganese, pH and other local conditions . On waters that
are pre-chlorinated or where other pre-oxidation occurs, precipitated metal oxides may form that are too fine to be filtered .
3
The pH listed is the minimum for the influent water .
4
Optimum pH adjustment occurs at 3 .0 gpm or less at maximum salt settings . Higher flow rates will produce less pH adjusted water .
5
Unit not tested for capacity at these flow rates . Water quality may vary .
MODEL
TC1-1044TW
TC1-1054TW
TC1-1354TW
TC2-1044TW
TC2-1054TW
TC2-1354TW
1
Capacity:
Maximum
11,800 @ 12 .4
22,600 @ 15 .9
36,900 @ 21 .2
20,300 @ 12 .4
34,800@ 15 .9
60,300 @ 26 .5
(Grains/Lbs . NaCI)
Medium
11,400 @ 9 .3
20,700 @ 12 .4
33,600 @ 15 .9
19,100 @ 9 .3
32,000 @ 12 .4
48,300 @ 15 .9
Minimum
7,300 @ 3 .2
16,400 @ 6 .1
28,300 @ 9 .5
11,100 @ 3 .2
22,900 @ 6 .1
28,200 @ 9 .3
Amount of Media (Cu . Ft .)
1 .0
1 .5
2 .5
1 .0
1 .5
2 .5
Maximum Water Hardness (GPG)
20
30
40
40
60
80
2
Maximum Iron and Manganese (PPM)
8 .0
10 .0
15 .0
8 .0
10 .0
15 .0
3
Minimum pH
6 .5
6 .0
6 .0
7 .0
7 .0
7 .0
4
Total pH Adjusted Water
510
510
863
NA
NA
NA
5
Peak Flow Rate (GPM @ P-PSI)
19 .0 @ 8 .3
17 .0 @ 7 .8
19 .0 @ 7 .6
19 .0 @ 9 .3
17 .0 @ 9 .1
19 .0 @ 8 .6
Continuous Flow Rate (GPM @ P-PSI)
9 .0 @ 2 .4
9 .0 @ 2 .8
9 .0 @ 2 .7
9 .0 @ 3 .0
8 .0 @ 3 .7
9 .0 @ 2 .8
Water Pressure Range (PSI)
2
5
-100
25-100
2
5
-100
2
5
-100
25-100
25-100
Water Temp . (ºF)
33-100
33-100
33-100
33-100
33-100
33-100
Electrical Requirements (volts-hertz)
110-50/60
110-50/60
110-50/60
110-50/60
110-50/60
110-50/60
Pipe Size
1”
1”
1”
1”
1”
1”
Total Dimensions:
Media Tank and Valve
23”W x 52”H
23”W x 62”H
29”W x 62”H
23”W x 52”H
23”W x 62”H
29”W x 62”H
Brine Tank
18”W x 33”H
18”W x 33”H
18”W x 40”H
18”W x 33”H
18”W x 33”H
18”W x 40”H
MODEL
TC1-1044TW TC1-1054TW TC1-1354TW TC2-1044TW TC2-1054TW TC2-1354TW
MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL.
Backwash
12 42 12 48 12 84 12 36 12 42 12 60
Brine & Rinse
72
29
90
36
90
72
72
29
90
36
90
72
Rapid Rinse
4
14
4
16
4
28
4
12
4
14
4
20
Brine Refill
5:51
3
9:53
5
11:53
6
5:51
3
9:53
5
11:53
6
Total
94 88 116 105 118 190 94 80 116 97 118 158
Height
Width