The 22 gauge wire crimp terminals are Molex Series 41572 or 40445. The housing connector is Molex Series 2695 White Housing, P/N 22-01-3037.
The housing connector diagram shows the proper installation of the RED,
WHITE and BLACK wires for CLACK CORPORATION CONTROL VALVES.
When connecting to other manufacturers control valves please contact your
original equipment manufacturer for proper wiring instructions.
Wiring:
• The meter must be supplied with a DC voltage between 4 and 24 volts
• The RED wire is positive
• The BLACK wire is negative
• The WHITE wire is the meter output
Calibration:
• For WS2H valves select 8 pulses if valve software records in gallons and 2.1 if valve software
records in liters.
• The calibration factor for the WS3 Meter Assembly is 8 pulses per gallon when used on
applications other than WS2H valves.
• The meter
fl
ow range is 3.5-350 gpm + 5% (output signal 0.46 Hz to 46.6 Hz). NOTE: Not all
fl
ow
monitors will register accurately at either the low or high
fl
ow range of this meter. Contact your
fl
ow monitor manufacturer for limitations.
• Pressure drop at 350 gpm is 7.3 PSI
Installation
Installation of the V3075 WS3 Meter NPT Assembly can be accomplished with 3” NPT pipe. For V3075BSPT WS3 Meter BSPT Assembly use
3”
BSPT pipe.
It is recommended that the meter assembly be installed horizontally or in a down
fl
ow vertical position to reduce turbine bearing wear.
WHEN INSTALLING THE METER, MAKE SURE THE ARROW ON THE METER BODY IS GOING THE SAME DIRECTION AS
THE WATER FLOW. THE METER CAN BE INSTALLED IN HORIZONTAL OR “UPFLOW” VERTICAL APPLICATIONS.
THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL OR HEALTH EFFECT
APPLICATIONS.
OPERATING PRESSURES: 20 PSI MINIMUM / 125 PSI MAXIMUM
OPERATING TEMPERATURES: 40°F MINIMUM / 110°F MAXIMUM
CLACK
CORPORATION
VALVES ONLY
V3221 WIRE
HARNESS
RED
WHITE
BLACK
RED AND WHITE LEADS
NOT INSERTED IN HOUSING
BLACK
V3095 WS3 Meter NPT MxF Assembly and V3095BSPT-15 WS3 Meter BSPT MxF Assembly
V3095-15 WS3 Meter ASY NPT MxF 15FT and V3095BSPT-15 WS3 Meter ASY BSPT MxF 15FT
Typical meter retaining clip installation.
Ensure clip is fully engaged in groove
and tabs positioned in slot as shown.
Drawing No.
Order No.
Description
V3095
V3095BSPT
V3095-15
V3095BSPT-15
1
V4039
WS3 METER COMMERCIAL ASY 4 FT CORD
(includes V3118-03, V3105 & V3501)
1
1
V3221
WS REMOTE METER ASY 15 FT CORD
(includes V3118-03, V3105 & V3501)
1
1
2
V3118-03
WS15/2 TURBINE ASY
1
1
1
1
3
V3105
O-RING 215
1
1
1
1
4
V3501
WS15/2 TURBINE CLIP
1
1
1
1
5
V3844-01
WS3 METER NPT MxF HOUSING
1
1
V3844BSPT-01 WS3 METER BSPT MxF HOUSING
1
1
6
V3632
WS1.5/2/3 METER RETAINING CLIP
1
1
1
1
Not shown
V3602
WS3 FLOW STRAIGHTENER
(located inside meter housing)
1
1
1
1
1
5
B indicates BSPT
N indicates NPT
2
3
4
6
Service or replace the turbine by:
1. Turn the bypass for the system off and relieve the pressure on the system.
2. Press downward on the remote meter assembly to relieve tension on the retaining clip V3632.
Remove the clip and take the meter assembly out of the housing.
3. Remove the bend from the two exposed tips of the retaining clip V3501 and remove clip.
4. Service or replace the V3118-03 WS15/2 Turbine Assembly and place it back in the turbine shaft.
5. Insert the V3501 WS15/2 Turbine Clip and re-bend the exposed ends of the clip. The V3118-03
turbine has a groove to line up with the V3501 WS15/2 Turbine Clip.
6. Insert meter assembly back into the meter housing.
7. Re-install the meter retaining clip V3632 as shown above.
8. Open the bypass for the system slowly to bring back into service and check to be sure you have
no water leaks.
WS2H and WS3 Drawings and Service Manual