Install D1300-01 upper diffuser (not shown) when using the 4” Quick Dissconnect (V3064)
1
2
3
4
5
6
7
8
10
9
15
16
18
19
17
11
12
13
B or indent
indicates BSPT
N or no mark
indicates NPT
14
Typical meter retaining clip installation.
Ensure clip is fully engaged in groove
and tabs positioned in slot as shown.
WS2H and WS3 Drawings and Service Manual
Page 17
WS2H Drive Cap Assembly, Down
fl
ow Piston, Regenerant Piston, Spacer Stack Assembly,
Drive Back Plate, Main Body and Meter
Drawing No.
Order No.
Description
Quantity
1
V3275
WS2H/3 SCREW BTNSKT HD SS3/8-16X2-1/4
(7/32” hex allen wrench required)
4
2
V3291
WS2H/3 WASHER SS 3/8
4
3
V3225
WS2H/3 BACK PLATE
1
4
V3066
WS2H DRIVE ASY
1
5
V3289
O-RING 344
1
6
V3204-01
WS2H PISTON
1
7
V3238-01***
WS2H/3 BRINE PISTON
1
8
V3065
WS2H STACK ASY
1
Not Shown
V3468
WS2H/3 PLUG 1/4 HEX NPT (included when ordering V3201-03)
2
V3465
WS2H/3 PLUG 1/4 HEX BSPT (included when ordering V3201BSPT-03)
9
V3201-03
WS2H BODY W/V3468 PLUG
1
V3201BSPT-03
WS2H BSPT BODY W/V3465 PLUG
10
V3632*
WS1.5/2/3 METER RETAINING CLIP
1
11
V3003-02
WS1.5/2H METER COMMERCIAL ASY
1
12
V3118-03
WS1.5/2 TURBINE ASY
1
13
V3105
O-RING 215
1
14
V3501
WS1.5/2 TURBINE CLIP
1
15
V3279
O-RING 346
1
16
V3280
O-RING 332 FOR VALVE BODIES WITH NPT THREADS
1
V3452
O-RING 230 FOR VALVE BODIES WITH BSPT THREADS
17
V3054**
WS2H 4 IN BASE CLAMP ASY
1
18
V3276
WS2H/3 BOLT HEX SS 5/16-18X1-3/4
1
19
V3269
WS2H/3 NUT 5/16-18 SS HEX
1
Not Shown
D1300-01
TOP BAFFLE DFSR CLACK 2/63MM
1
* In 2008 a modi
fi
cation was made to Meter Housings to use V3632 WS1.5/2/3 Meter Retaining Clip. Do not use V3632 on old style housings which have holes through the castings to
accept the U-shaped V3223 WS2 Meter Clip.
**V3054 WS2 4 IN BASE CLAMP ASY includes a V3276 WS2 BOLT HEX SS 5/16-18X1-3/4 and V3269 WS2 NUT 5/16-18 SS HEX.
***V3238-01 Brine Piston is used for Backwash Only valves.
THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL OR HEALTH EFFECT APPLICATIONS.
Service or replace the turbine by:
1. Turn the bypass for the system off and relieve the pressure on the system.
2. Press downward on the remote meter assembly to relieve tension on the retaining clip V3632 (or the U-shaped V3223 WS2 Meter Clip). Remove the clip and take
the meter assembly out of the housing.
3. Remove the bend from the two exposed tips of the retaining clip V3501 and remove clip.
4. Service or replace the V3118-03 WS15/2 Turbine Assembly and place it back in the turbine shaft.
5. Insert the V3501 WS15/2 Turbine Clip and re-bend the exposed ends of the clip. The V3118-03 turbine has a groove to line up with the V3501 WS15/2 Turbine Clip.
6. Insert meter assembly back into the meter housing.
7. Re-install the meter retaining clip V3632 as shown below (or the U-shaped V3223 WS2 Meter Clip).
8. Open the bypass for the system slowly to bring back into service and check to be sure you have no water leaks.