Page 18
WS2H and WS3 Manual
SYSTEM SETUP 7
SYSTEM SETUP 7 - Set the ionic capacity of the tank
• Only available for US based measurements
• Used for auto caculation of unit capacity
SYSTEM SETUP 6 – Set unit capacity
• Only available for US based measurements
• Allows for automatic calculation of tank capacity or user entered capacity
SYSTEM SETUP 6
SYSTEM SETUP SCREENS (CONTINUED)
SYSTEM SETUP 8 - Day override control
• 28 day time clock: Used to regenerate units based on a set number of days between
regenerations
• 7 Day Time Clock: Used to control regeneration based on specifi c days
• OFF: Days have no control on regenerations, and will not be a selection if volumetric
capacity is set to OFF
SYSTEM SETUP 8
Separate Source
• Each unit has isolation to control system operation and will not supply service water during regeneration
• Drive timing will keep units isolated through the entire regeneration sequence
Simple Alt Sharing MAV
• Only available when set to a 2 unit alternator
• A “Simple 2 Unit” shares one MAV to be electrically connected to the bypass connection of the “B” (slave) unit
Relay
• Only available when when the optional relay exansion module is installed and one or both of the relays is set for
Standby
• Isolation will be done through the optional relay expansion module and does not initialize the BYPASS motorized
drive circuit
Simple Alt Sharing MAV
• Only available when set to a 2 unit alternator
• A “Simple 2 Unit” shares one MAV to be electrically connected to the bypass connection of the “B” (slave) unit
Summary of Contents for WS2H
Page 2: ...Page 2 WS2H and WS3 Manual...