WS2H and WS3 Manual
Page 49
M X F STAINLESS STEEL, 0.7 – 150 GPM
Assemblies are shipped without drain line fl ow control (DLFC). Assembly instructions:
1. Determine the desired fl owrate. Select a combination of V3162-XXX’s and V3190-XXX’s to arrive at the
desired fl ow rate. Up to fi ve of the smaller V3162-XXX’s may be used. Up to four of the larger V3190-XXX’s
may be used.
2. Using a drill or punch remove the desired knockout(s) in V3052.
3. Smooth
hole(s).
4. Install appropriate size(s) of drain line fl ow control washers. Pay close attention to proper DLFC orientation.
5. Assemble. Properly orientate the V3052 in the direction of fl ow.
6. Inlet and outlet threads are 2”. Couplings for iron pipe may also be used.
1
2
5
3
4
Dir
ection of Flow
B indictates BSPT
N indicates NPT
Washer
Radius
Direction
of Flow
Drawing
No.
Order
No.
Description
Quantity
V3051
V3051BSPT
1
V3052
WS2 DLFC Retainer Asy
1
1
2
V3245
WS2 DLFC Flange Inlet NPT
1
V3245BSPT
WS2 DLFC Flange Inlet BSPT
1
3
V3246
WS2 DLFC Flange Outlet NPT
1
V3246BSPT
WS2 DLFC Flange Outlet BSPT
1
4
V3273
Bolt Hex Hd S/S HCS 3/8-16x3/4
4
4
5
V3278
O-ring 338
1
1
6
V3162-XX
See DLFC table
0-5
0-5
7
V3190-XX
See DLFC table
0-4
0-4
Summary of Contents for WS2H
Page 2: ...Page 2 WS2H and WS3 Manual...