INTELLIZONE2 SPECIFICATION CATALOG
IntelliZone2 Confi guration cont.
Humidity
Humidify
- Turns on the H output when the room
humidity is below the set point and there is an
active heating call
Dehumidify
– Turns on the DH output when the room
humidity is above the set point and the MODE
is set to COOL or AUTO when Cool was the last
mode run.
-Turns on Active Dehumidification (VS Systems)
Both
– HUMIDIFY operates in the HEAT mode and
DEHUMIDIFY operates in COOL mode.
NONE
– Neither is active.
Temperature Sensors
- Allows selection of the remote
sensor to determine outdoor or indoor temperature.
Because IntelliZone2 ships standard with an outdoor
sensor, this option needs to be selected.
NOTE:
LAS = OAT on IntelliZone2 relay board.
Accessories
-
Each of these options has settings for Cumulative Run Time
and Calendar Time. Messages will flash at the top of the
Main screen when these events are met to alert the owner
that it is time service these options.
Air Filter
- Cumulative Run Time default is 1000 hours
and Calendar Time is 3 months. Values can range
from NONE-2500 hours for Cumulative Run Time
(in 100 hour increments), or Calendar Time can be
set to NONE to 12 months (in 3 month increments).
Humidifier
- Cumulative Run Time default is NONE
hours (OFF) and Calendar Time is NONE. Values
can range from NONE, 400-2500 hours for
Cumulative Run Time (in 100 hour increments), or
Calendar Time can be set to NONE to 12 months
(in 3 month increments).
UV Lamp
- Cumulative Run Time default is NONE
hours (OFF) and Calendar Time is NONE. Values
can range from NONE, or 400-3600 hours for
Cumulative Run Time (in 100 hour increments), or
Calendar Time can be set to NONE to 48 months
(in 3 month increments).
Air Cleaner
- Cumulative Run Time default is NONE
(OFF) and Calendar Time is NONE. Values can
range from NONE, 400-2500 hours for Cumulative
Run Time (in 100 hour increments), or Calendar
Time can be set to NONE to 12 months (in 3 month
increments)
Dealer Information
- Allows the input of the dealer
name, phone, address, e-mail and website. Simply press
the screen segment where you want to enter information
and a keypad will appear.
Fault Status
- Shows the last 10 IntelliZone2 system Faults
(heat pump fault history is displayed at the heat pump on
the AID Tool). The faults can be cleared or refreshed from
this screen.
Restore Defaults
- This will allow you to revert to the
factory default settings.
Restart Thermostat/Upgrade Software
- This allows a
convenient way to restart the thermostat or upload the
latest software using the USB port without killing power to
the whole system.
USB
- Allows the import and export of data using the USB port.
Importation of:
Installer settings, User Settings, Program,
Dealer Details
Exportation of:
Installer settings, User Settings, Program,
Dealer Details
Data Logging
- Allows the USB thumb drive to record the data
every 5 seconds. Data should not be collected for more than
a one week period. Collecting data more than one week will
create a file too large to read.
F°/C°
- Allows selection of either Fahrenheit or Celsius
temperature scale.
Residential, Commercial
- Future Use
Energy Demo
- These screens allow a dealer to show
the end user an example of the information that will be
displayed on daily and monthly screens once their system
is operating. This is only an example and not actual data
from their system.
Photo Upload
- The Intellizone2 will allow personal photo
upload to be displayed once the thermostat goes into
sleep mode. The MasterStat can only accept photos that
are TCI format. Common photo formats can be converted
to the TCI format, which is used by the thermostat, by
using our photo converter software. Once the photos
have been converted and uploaded to the MasterStat they
will be displayed as a slide show when the thermostat
goes into sleep mode. Sleep mode occurs after 5 minutes
of inactivity (no screen touches). The photo conversion
software and instructions for uploading the photos can be
found at www.auroracontrols.com.