Bag #23834A004
9
23833A09
Thread 10" x 1" nipple into pressure tank.
Thread tank cross #RTC290-1 into nipple so that
the two 1/4" holes in tank cross face upward.
Thread street tee into front of tank cross. Thread
pressure relief valve #RRV-75 into top of street
tee and thread 3/4" boiler drain into front of
street tee.
STEP
3
STEP
1
Process D: Steps 1 through 4,
At The House
Installing a submersible well pump, continued.
Thread one end of 1/4" x 3" brass nipple into
bottom of pressure switch #RPS. Thread other end
into left 1/4" hole of tank cross. Thread pressure
gauge #RG-2 into right 1/4" hole of tank cross.
Cut and cement as many sections and couplings
of PVC pipe needed to connect the 1" male
PVC adapter on the gate valve to 1" male PVC
adapter on the pitless slot assembly. Complete
installation should look like the drawing on the
following page.
T
3/4" BOILER
DAIN
ANK CROSS
#RTC 290-1
3/4" PRESSURE
RELIEF VALVE
#RRV-75
PRESSURE
SWITCH #RPS
PRESSURE
GAUGE
#RG-2
1/4" X 3"
NIPPLE
1" MALE PVC
ADAPTER
T
3/4" BOILER
DAIN
ANK CROSS
#RTC 290-1
3/4" PRESSURE
RELIEF VALVE
#RRV-75
PRESSURE
SWITCH #RPS
PRESSURE
GAUGE
#RG-2
1/4" X 3"
NIPPLE
1" MALE PVC
ADAPTER
A typical submersible well
pump installation
STEP
2
Thread 1" male PVC adapter into the inlet side
of tank cross.
T
3/4" BOILER
DAIN
ANK CROSS
#RTC 290-1
3/4" PRESSURE
RELIEF VALVE
#RRV-75
PRESSURE
SWITCH #RPS
PRESSURE
GAUGE
#RG-2
1/4" X 3"
NIPPLE
1" MALE PVC
ADAPTER
CONSUMER HOT-LINE:
1-800-942-3343
(USA only)
Monday–Friday 7 AM to 5 PM EST
www.waterace.com