STEP 1

Carefully tie a small but heavy weight to the end of a piece 
of string (be sure there is enough string; some wells are very 
deep). Lower weight into well until it reaches bottom.

STEP 2

Take up slack and mark string at ground level. Pull weight out 
of  well  and  measure  from  bottom  of  weight  to  ground  level 
mark. This is the depth of your well. 

STEP 3

*Subtract  ten  feet  from  this  depth.  This  number  should  not 
exceed  the  pumping  depth  of  your  pump.  If  it  does,  it  will 
prevent the proper operation of the pump. 

STEP 4

Subtract twelve feet from the depth of your well. This is the 
approximate length of polytubing or piping needed to install 
pump. Now you should know the depth of your well.  Please read 
the entire installation manual carefully before you begin the 
well pump installation.  

If you require assistance with your 

well pump installation, please call the Water Ace consumer 

hot-line: 1-800-942-3343 or access www.waterace.com for 

additional information.

WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS AND 

COMPLY WITH ALL CODES MAY CAUSE SERIOUS BODILY 

INJURY AND/OR PROPERTY DAMAGE.

BEFORE YOU BEGIN, YOU SHOULD KNOW THE DEPTH OF YOUR WELL.  WATER ACE SUGGESTS THE 

FOLLOWING FOUR EASY STEPS IN DETERMINING YOUR WELL DEPTH.

 

  2-WIRE MODELS

R200A

 PART NO. 2320D500, /2 HP, 0 GPM, 5 V

R201A

 PART NO. 2324D500, /2 HP, 0 GPM

R202A

 PART NO. 2328D500, 3/4 HP, 0 GPM

R203A

 PART NO. 23222D500,  HP, 0 GPM

R214A

 PART NO. 23225D500, 

/

2

 HP, 6 GPM

R2254A

 PART NO. 24350D503, 

/

2

 HP, 25 GPM

R2354A

 PART NO. 24350D505, 

/

2

 HP, 35 GPM

  3-WIRE MODELS

R300A

 PART NO. 23242D500, /2 HP, 0 GPM

R301A

 PART NO. 23246D500, 3/4 HP, 0 GPM

R302A

 PART NO. 23250D500,  HP, 0 GPM

R3065A

 PART NO. 23240D500, /2 HP, 6 GPM

R3067A

 PART NO. 23244D500, 3/4 HP, 6 GPM

R30610A

 PART NO. 23248D500,  HP, 6 GPM

R31015A

 PART NO. 23254D500, 

/

2

 HP, 0 GPM

R314A

 PART NO. 23253D500, 

/

2

 HP, 6 GPM

R3183A

 PART NO. 2325D500,  HP, 8 GPM

R3184A

 PART NO. 23255D500, 

/

2

 HP, 8 GPM

R3207A

 PART NO. 23247D500, 3/4 HP, 8 GPM

R3254A

 PART NO. 24350D502, 

/

2

 HP, 25 GPM

R3354A

 PART NO. 24350D504, 

/

2

 HP, 35 GPM

Typical 3-4 bedroom home requires 8-12 GPM

Note: If your well depth is over 200 feet 
deep you may want to consider contacting 
a professional well pump installer to assist 
you. 

 Piping filled with water in conjunction 

with the weight of the pump can become 
very heavy. Please seek assistance during 
the well pump installation or dismantling.

*Ten  feet  above  the  bottom  well  is  the 
maximum  setting.  The  draw  down  is  the 
lowest water level after the pump is turned 
on.  Well pumps can be set ten (0) feet 
below  the  draw  down,  if  the  draw  down  
is known.

Knowing Your Well Depth

(Rev. /6/05)

Summary of Contents for R200A

Page 1: ...CAUSE SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE BEFORE YOU BEGIN YOU SHOULD KNOW THE DEPTH OF YOUR WELL WATER ACE SUGGESTS THE FOLLOWING FOUR EASY STEPS IN DETERMINING YOUR WELL DEPTH 2 WIRE MODEL...

Page 2: ...rounding means and to all metal parts accessible at the well head including metal discharge pipes metal well casing and the like by means of the following b1 An equipment grounding conductor at least...

Page 3: ...burnout Refer to the performance table on page 4 to determine which pump best fits your needs The performance table illustrates each model s pumping capacity in gallons per minute GPM as compared to...

Page 4: ...8 5 R301A R3067A 6 3 4 7 7 7 6 7 4 7 0 6 6 6 2 5 8 5 0 R3207A 18 3 4 15 3 R203A 10 1 14 4 13 4 12 1 10 7 9 3 7 4 R302A R30610A 6 1 8 0 7 9 7 7 7 5 7 2 6 9 6 5 5 7 5 0 4 2 R3183A 18 1 22 5 21 2 20 0 R...

Page 5: ...k tube over crimped joint Apply heat with torch or butane lighter Heat one tube at a time see figure C Do not let tubes touch each other while heating When liquid oozes from end of tube seal is comple...

Page 6: ...where it is damaged or has a leaky splice It must be repaired with a cable splice kit Installing a submersible well pump continued Process A Steps 1 through 5 At The Pump Cable Continued Splice Check...

Page 7: ...ing Place other washer fitting and lock nut on slot threads protruding from casing Tighten securely The slot has interior threads as well Thread a 1 male PVC adapter into the slot see figure L With so...

Page 8: ...TERS MINIMUM CHECK VALVE EVERY 200 FT 60 METERS SAFETY CABLE Process C Step 1 only Lowering The Pump With someone s help carefully lower pump assembly into well Slide pitless pipe junction into pitles...

Page 9: ...pressure gauge RG 2 into right 1 4 hole of tank cross Cut and cement as many sections and couplings of PVC pipe needed to connect the 1 male PVC adapter on the gate valve to 1 male PVC adapter on the...

Page 10: ...of the ground screws at base of pressure switch Run wires from control box terminals labelled L1 and L2 to two inside pressure switch terminals numbers 2 3 Run wires from two outside pressure switch...

Page 11: ...5 VOLT HOOKUP A SINGLE POLE BREAKER IS USED THIS BREAKER CONTACTS ONLY ONE BUSS BAR THE GROUND IS HOOKED TO THE NEUTRAL BAR THE WHITE WIRE IS ALSO HOOKED UP TO THE NEUTRAL BAR GREEN GROUND BLACK POWER...

Page 12: ...INSTRUCTIONS IN THE INSTALLATION MANUAL WHEN IN DOUBT CONSULT A PROFESSIONAL Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or excl...

Page 13: ...nnue D terminer la profondeur d un puits TAPE 1 Attachez soigneusement un petit poids relativement lourd l extr mit d une corde assurez vous d avoir une corde assez longue car certains puits sont tr s...

Page 14: ...e m tallique du puits et autre gr ce au mat riel suivant b1 Un conducteur de mise la terre d quipement dont la grosseur est au moins quivalente aux conducteurs du c ble du puits ou l quivalent qui des...

Page 15: ...convient le mieux vos besoins veuillez consulter le tableau de performances de la page 4 Ce tableau de performances indique les capacit s des divers mod les de pompes en gallons par minute GPM avec d...

Page 16: ...7 4 7 0 6 6 6 2 5 8 5 0 R3207A 18 3 4 15 3 R203A 10 1 14 4 13 4 12 1 10 7 9 3 7 4 R302A R30610A 6 1 8 0 7 9 7 7 7 5 7 2 6 9 6 5 5 7 5 0 4 2 R3183A 18 1 22 5 21 2 20 0 R31015A 10 1 1 2 14 9 14 3 13 6 1...

Page 17: ...che est termin Reportez vous en page 6 sous V rification des pissures pour vous assurer qu il n y a pas de fuite TAPE 1 TAPE 2 Quelle est la proc dure suivre pour installer une pompe de puits submersi...

Page 18: ...ond l endroit o le c ble est endommag ou au site de l pissure d fectueuse Effectuez la r paration avec un kit d pissage Installation d une pompe de puits submersible suite Proc dure A tapes 1 5 sur la...

Page 19: ...connecteur est galement dot e d un filetage int rieur Vissez un adaptateur en PVC m le de 1 po dans le connecteur voir la figure L Avec l aide de quelqu un descendez soigneusement la pompe dans le pui...

Page 20: ...tion de pompe submersible DESCENTE DE LA POMPE FOND DU PUITS MINIMUM 10 PI 3 M NIVEAU DE CHUTE RETENIR LE C BLE AVEC DU RUBAN ADH SIF TOUS LES 10 PI 3 M MINIMUM 5 PI 1 5 M CLAPET ANTI RETOUR TOUS LES...

Page 21: ...it ressembler au sch ma de la page suivante CROIX DE R SERVOIR RTC 290 1 COULEMENT DE CHAUDI RE DE 3 4 PODAIN SOUPAPE DE D CHARGE RRV 75 DE 3 4 PO ADAPTATEUR EN PVC M LE DE 1 PO MAMELON 1 4 PO X 3 PO...

Page 22: ...s du pressostat n 2 et 3 Faites passer des fils depuis les deux bornes l ext rieur du pressostat n 1 et 4 jusqu la bo te de fusibles ou d entr e lectrique Faites passer un fil depuis la vis de terre j...

Page 23: ...IONNERA M ME SI L UN DES DEUX EST D CLENCH DANS CE CAS L APPAREIL NE FONCTIONNE PAS MAIS LE MOTEUR PEUT QUAND M ME TRE SOUS TENSION ET LECTROCUTER QUELQU UN DANGER LE RACCORDEMENT SOUS 230V DES DEUX D...

Page 24: ...ou cons cutifs il est possible que l exclusion ou restriction ci dessus ne s applique pas vous Cette garantie vous accorde des droits juridiques pr cis mais il est possible que vous ayez galement d au...

Page 25: ...n el extremo de una cuerda aseg rese de que haya cuerda suficiente algunos pozos son muy profundos Baje el peso por el pozo hasta llegar al fondo PASO 2 Tense la cuerda y m rquela a nivel del suelo Sa...

Page 26: ...metal accesibles en el cabezal del pozo incluidas las tuber as met licas de descarga el revestimiento met lico del pozo y a otros elementos similares mediante lo siguiente b1 Un conductor de conexi n...

Page 27: ...recuencia lo que podr llevar a quemar el motor Consulte la tabla de rendimientos de la p gina 4 para determinar la bomba que mejor se ajuste a sus necesidades La tabla de rendimiento ilustra la capaci...

Page 28: ...7 7 7 6 7 4 7 0 6 6 6 2 5 8 5 0 R3207A 18 3 4 15 3 R203A 10 1 14 4 13 4 12 1 10 7 9 3 7 4 R302A R30610A 6 1 8 0 7 9 7 7 7 5 7 2 6 9 6 5 5 7 5 0 4 2 R3183A 18 1 22 5 21 2 20 0 R31015A 10 1 1 2 14 9 14...

Page 29: ...ello es tar completo V ase la secci n de Revisi n de empalmes del cable en la p gina 6 para verificar si hay fugas PASO 1 PASO 2 C mo instalo una bomba sumergible para pozos Reste doce pies a la profu...

Page 30: ...able est da ado o tenga un empalme con p rdida Deber repararse con un juego de empalmes para cables Instalaci n de una bomba sumergible para pozo continuaci n Proceso A pasos 1 al 5 Con el cable de la...

Page 31: ...stimiento Apriete bien La ranura tiene tambi n roscas interiores Enrosque un adaptador macho de cloruro de polivinilo de 1 pulgada en la ranura v ase la ilustraci n L Con la ayuda de alguna persona ba...

Page 32: ...ca de una bomba sumergible para pozos con sello DESCENSO DE LA BOMBA FONDO DEL POZO M NIMO DE 10 PIES 3 METROS NIVEL DE AGUA DE BOMBEO UNA EL CABLE CON UNA CINTA CADA 3 METROS M NIMO DE 5 PIES 1 5 MET...

Page 33: ...uro de polivinilo como sea necesario para conectar el adaptador macho de cloruro de polivinilo de 1 pulgada en la v lvula de compuerta al adaptador macho de cloruro de polivinilo de 1 pulgada en la en...

Page 34: ...internas del interruptor de presi n n meros 2 y 3 Instale los conductores desde las dos terminales exteriores del interruptor de presi n l neas 1 y 4 hasta el suministro el ctrico o a la caja de fusi...

Page 35: ...TIERRA DE LA CASA CONDUCTOR DE CONEXI N A TIERRA VERDE NEGRO POTENCIA DISYUNTOR DEL CIRCUITO PRINCIPAL BARRAS COLECTORAS CONDUCTORES DE SUMINISTRO EL CTRICO DE LA EMPRESA PROVEEDORA DE SERVICIO EL CT...

Page 36: ...no ser aplicable en su caso Esta garant a le da derechos legales espec ficos y podr a tener tambi n otros derechos los cuales variar n de estado a estado En caso de ausencia de comprobante adecuado d...

Reviews: