Body Temperature Detection Camera
User Manual
www.watchnetinc.com
62
Parameter Description
Setting
Limit
Target Size
The target size for triggering an
effective alarm is set based on the
actual target size. The minimum size
is 1000 square centimeters and the
maximum 100000 square
centimeters. When setting the target
size, you need to well set “Real size
in scene” in advanced parameters,
otherwise no alarms may be
generated.
[How to set]
Click to enable Limit
Target Size.
[Default configuration]
OFF
Upload
Target Info
Enable the function of uploading
target information by clicking
below the real-time video in a
browser to turn
into
.
When an alarm is triggered, the
target movement trace can be
displayed (The trace can be seen
only within the deployment area and
disappears after the target leaves the
deployment area).
[How to set]
Click to enable Upload
Target Info.
[Default value]
OFF
Pass Max
Time (Sec)
An alarm is generated only when the
time taken to cross the double virtual
fences is less than the value. The
default value is 10 seconds and the
setting range is 1-60 seconds.
[How to set]
Enter a value in the area
box.
Output
Channel
If you check to set the Output
Channel and the device is connected
to an external alarm indicator, the
alarm indicator signals when an
alarm is triggered.
[How to set]
Click to select an ID.
Alarm
Record
Enable the button to enable the
alarm record.
[How to set]
Click to enable Alarm
Record.
[Default value]
OFF
SMTP
Enable the button to enable SMTP
sever.
[How to set]
Click to enable SMTP.
[Default value]
OFF