background image

12

Single gas detector

PDM 

8. CERTIFICATES

Intrinsic Safety:

The detector is in conformity of the following standards

IECEx:        

Ex ia IIC T4 Ga

IECEx KTL 15.0018

Ex ia IIC T4 Ga

Class I, Zone 0, AEx ia IIC T4 Ga

Class I, Division 1, Groups A, B, C, D, T4

C22.2 No. 60079-0:2015; C22.2 No. 60079-11:2014;

C22.2 No. 61010-1-12:2010; UL 61010-1,

Ed. 3; UL 913, Ed. 8; UL 60079-0, Ed. 6; UL 60079-11, Ed. 6

ATEX:        

 2198 

 II 1 G Ex ia IIC T4 Ga IP67 

KRH16ATEX1048

Directive 2014/34/EU

KCS:           Ex ia IIC T4

KTL 16-KA2BO-0457

INMETRO      Ex ia IIC T4 Ga

BVC16.5919/02

Compliance: 

Electromagnetic Compatibility Directive 2014/30/EU

Standards:

The electrical apparatus and any acceptable variations to it specified in the schedule of this

certificate and the identified documents, was found to comply with the following standards:

•  IEC 60079 0: 2011 Ed. 6

•  IEC 60079 11: 2011 Ed 6

•  UL 61010 1, Ed. 3

•  UL 913, Ed. 8

•  UL 60079 0, Ed. 6

•  UL 60079 11, Ed. 6

•  C22.2 No. 60079 0:2015

•  C22.2 No. 60079 11:2014

•  C22.2 No. 61010 1 12:2012

•  EN 60079 0: 2012+A11:2013

•  EN 60079 11: 2012

Manufacturing Approval:

The detector manufacturer is certified compliant with ISO 9001:2000 provisions

Summary of Contents for PDM

Page 1: ...USER MANUAL Single gas detector PDM we watch gas where you can t...

Page 2: ...5 3 3 Alarms Battery Test Failure display 6 3 4 Alarm Set Points 7 3 5 Default Calibration Concentrations 7 4 EVENT LOG 7 5 CALIBRATION 7 5 1 Fresh Air Calibration 7 5 2 Standard Gas Calibration 8 5...

Page 3: ...of the device e g indoors vs outdoors the value of the measured gas concentration can suddenly change Please use the PDM after the gas concentration value has stabilized Severe vibration or shock to...

Page 4: ...R communication port 1 PRODUCT OVERVIEW 3 6 1 2 4 DISPLAY SYMBOLS 5 6 7 Alarm Low Alarm High Alarm Stabilization Success Failure Fresh Air Calibration Standard Gas Calibration Remaining Months Remaini...

Page 5: ...ion CAUTION Appropriate calibration of the device is required prior to operation Always ensure that the device makes the proper detection response to the pertinent gas Verify that debris that could in...

Page 6: ...crease and the alarm will stop Alarm Alarm standard LCD Display Alarm and Vibration 1st Alarm Exceeds 1st alarm Icon concentration 2nd Alarm Exceeds 2nd alarm Icon concentration Remaining Life Below 3...

Page 7: ...a WatchGas IR Link Each alarm event is recorded as follows Types of alarms Alarm concentration in ppm or Peak concentration 5 CALIBRATION CAUTION Initial calibration is performed on all devices prior...

Page 8: ...5 2 STANDARD GAS CALIBRATION Attach the calibration adapter to the PDM and to a gas cylinder with a concentration matching the calibration concentration Check 3 1 Display Mode to check the calibratio...

Page 9: ...ration always verify sensor response and alarm functionality prior to using the detector by applying a known concentration of gas from another gas cylinder 5 3 REMAINING CALIBRATION DAY In the standar...

Page 10: ...ce the bump test interval expires Bts message will flash Put the PDM in the docking station with a valid and full gas cylinder Alternatively attach the calibration adapter to PDM and a valid and full...

Page 11: ...Lithium Primary Battery SB AA02 P 3 6V 1 2Ah MEASUREMENT Diffusion HOUSING Polycarbonate and rubber ACCURACY DEVIATION 2 3 IP RATING IP67 SAFETY CERTIFICATIONS ATEX II 1G Ex ia IIC T4 Ga CSA Class 1...

Page 12: ...S Ex ia IIC T4 KTL 16 KA2BO 0457 INMETRO Ex ia IIC T4 Ga BVC16 5919 02 Compliance Electromagnetic Compatibility Directive 2014 30 EU Standards The electrical apparatus and any acceptable variations to...

Page 13: ...rty s misuse neglect or improper installation testing or calibrations Any unauthorized at tempt to repair or modify the product or any other cause of damage beyond the range of the intended use includ...

Reviews: