background image

AM-215A Series 

RS-

485 User’s Manual

 

 

1. 

Overview

 

This manual explains the specifications of the communication functions provided by the AM -215A series of digital 

panelmeters.    It also explains how to handle the AM -215A series. 

 

2.

   

Specifications

 

 

 

 

 

 

 

 
 
 
 
 
 
 

3.

 

Terminal Assignments and Connection Method

 

3.1.

 

Terminal Assignments

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User’s Manual  AM-215A Series RS-485

 

                                                                    1/8 

UX-34109f 

2017.02   

Synchronization

:

Communication method

:

Transmission rate

:

Number of start bits

:

Data length

:

Error detection

:

Number of stop bits

:

Character code

:

Transmission control procedure

:

Signal name used

:

Number of units that can be connected

:

Transmission line length

:

Delimiter

:

Parity bit

:

Start-stop
Two-wire half-duplex (polling/selecting)
2400, 4800, 9600, 19200, 38400 bps
1bit
7bits, 8bits
Even parity, odd parity, or no parity
Block check character (BCC) checksum
1bit, 2bits
ASCII
CR+LF, CR
Non-procedural
Non-inverting (+), inverting (-)
31 for meters
500 m max. (overall length)
*In EN conformity, it is under 30m.

+24V

10

0V

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

COM

a

c

a

c

a

c

OUT3

OUT2

OUT1

+V

0V

POWER

HI

LO

+

-

DZ

TERMINATOR

RS485

INPUT

EXC

POWER

!

(c)

(e)

(c)

(e)

(c)

(e)

Note: A terminator will be set to being turned on if No. 5 and No. 6 are short-circuited. 

WATANABE ELECTRIC INDUSTRY CO., LTD.

 

Summary of Contents for AM-215A

Page 1: ...TOR ANALOG OUT or RS485 INPUT EXC POWER c e c e c e AL1 AL2 SET POINT COMPARATOR AM 215A INSTRUCTION MANUAL Caution 1 The equipment may be damaged if the input current or voltage exceeds the maximum...

Page 2: ...y When using a 2 wire sensor terminals 2 11 should be externally connected 4 When no terminals are selected for outputting do not connect anything to vacant terminals AL1 AL2 Condition data A group of...

Page 3: ...et The default value is 9999 The default value is 9999 A menu is displayed only the option output form 4 The default value is 0 A displayed value to obtain an output from the full scale side of the an...

Page 4: ...g temperature and humidity ranges 0 to 50 C 35 to 85 RH no condensation Storage temperature and humidity ranges 20 to 70 C 60 or lower RH no condensation Supply voltage DC 24 V 20 Consumed power Appro...

Page 5: ...inearity compensation of the rectifying point 2 is inputted The input value display value before linearity compensation of the rectifying point 16 is inputted The output value display value before lin...

Page 6: ...ransmission control procedure Signal name used Number of units that can be connected Transmission line length Delimiter Parity bit Start stop Two wire half duplex polling selecting 2400 4800 9600 1920...

Page 7: ...to ON AL1 AL2 AL1 AL2 AL1 AL2 AL1 AL2 Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Char Length 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Char Length Establishment of...

Page 8: ...0 H I CR LF 10 reading w o decimal point 5 0 0 0 H I CR LF 11 reading w decimal point 9 8 0 0 H I CR LF 10 overrange reading w o decimal point 9 8 0 0 H I CR LF 11 overrange reading w decimal point M...

Page 9: ...3 Response with the status of the hold function being remote controlled D Z R CR LF 3 Response with the status of the digital zero function being remote controlled R L Y CR LF 3 Response with the sta...

Page 10: ...T 1 W 1 CR LF 14 Response with the status of the tracking zero time being 1 and tracking zero width being 1 T R K O N T 9 9 W 9 9 CR LF 16 Response with the status of the tracking zero time being 99 a...

Page 11: ...O side logic function being set to N C N CR LF 1 L L O N O CR LF 8 Response with the status of the LO side logic function being set to N O L L O N C CR LF 8 Response with the status of the LO side log...

Page 12: ...on correction data items being 16 Setting for number of linearization L N O 0 2 CR LF 6 Y E S CR LF 5 correction data items Sets the number of linearization correction data items to 02 L N O 1 6 CR LF...

Page 13: ...unication parameter failure Note Under normal conditions this response is made only once Note ERROR B to ERROR F are available as the response commands for acknowledgment Note If a response to the ERR...

Reviews: