background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User’s Manual AM-215A Series RS-485

                                                                       7/8 

Scaling data response

M

E

T CR LF

3

F

S

C

9

9

9

9 CR LF

10

Note: The reading of the main unit changes to MET the moment it receives an MET command.

(Response with a full-scale reading.)

N CR LF

1

F

I

N

9

9

9

9 CR LF

10

(Response with a full-scale input value.)

N CR LF

1

O

F

S

0 CR LF

10

(Response with an offset reading.)

N CR LF

1

O

I

N

0 CR LF

10

(Response with an offset input value.)

N CR LF

1

D

L

H

I

9

9

9

9 CR LF

10

(Response with the HI value of the digital limiter.)

N CR LF

1

D

L

L

O

-

9

9

9

9 CR LF

10

(Response with the LO value of the digital limiter.)

N CR LF

1

D

E

P

4 CR LF

6

(Response with the position of the decimal point.)

R CR LF

1

Y

E

S

CR LF

5

Scaling data setting

M

E

T CR LF

3

F

S

C

9

9

9

9 CR LF

10

Note: This example shows a case

Note: The reading of the main unit changes to MET the moment it receives an MET command.

where FSC is set to 8000 and OFS

8

0

0

0 CR LF

4

F

S

C

8

0

0

0 CR LF

10

to 20.

(Sets the full-scale reading to 8000.)

N CR LF

1

F

I

N

9

9

9

9 CR LF

10

N CR LF

1

O

F

S

0 CR LF

10

2

0 CR LF

2

O

F

S

2

0 CR LF

10

(Sets the offset reading to 20.)

R CR LF

1

Y

E

S

CR LF

5

E

r

r

o

r

CR LF

6

(Response when a value outside the setpoint range is input.)

Linearization function status

L

I

N CR LF

3

L

I

N

O

F

F CR LF

7

response

(Response with the status of the linearization function being set to OFF.)

L

I

N

O

N CR LF

6

(Response with the status of the linearization function being set to ON.)

L

I

N

C

L

R CR LF

7

(Response with the status of the linearization function being cleared.)

Linearization function status setting

L

I

N

O

F

F CR LF

7

Y

E

S

CR LF

5

(Sets the linearization function to an OFF status.)

L

I

N

O

N CR LF

6

Y

E

S

CR LF

5

(Sets the linearization function to an ON status.)

L

I

N

C

L

R CR LF

7

Y

E

S

CR LF

5

(Sets the linearization function to a cleared status.)

N

O

?

CR LF

5

(Response with the status of the linearization function being cleared.)
Note: Since the linearization data are all cleared when the linearization function
is cleared, the main unit does not accept either a LIN ON or LIN OFF command.
(Set the linearization function status after setting the linearization data again.)

Response for number of linearization

L

N

O CR LF

3

L

N

O

0

0 CR LF

6

correction data items

(Response with the status of the linearization function being cleared.)

L

N

O

0

2 CR LF

6

(Response with the status of the number of linearization correction data items
being 02.)

L

N

O

1

6 CR LF

6

(Response with the status of the number of linearization correction data items
being 16.)

Setting for number of linearization

L

N

O

0

2 CR LF

6

Y

E

S

CR LF

5

correction data items

(Sets the number of linearization correction data items to 02.)

L

N

O

1

6 CR LF

6

Y

E

S

CR LF

5

(Sets the number of linearization correction data items to 16.)

E

r

r

o

r

CR LF

6

(Response when linearization data is not correctly set.)
Note: Set the number of linearization correction data items after setting
linearization data.)

Linearization data response

L

N

D

0

1 CR LF

6

L

N

D

0

1

I

=

0 CR LF

14

Note: A reading can be made from any of the data items 01 to 16.

(Response with the input value of linearization data N-01.)

Note: The reading of the main unit changes to LINE the moment it receives an LND XX
command.

N CR LF

1

L

N

D

0

1

O

=

0 CR LF

14

(Response with the output value of linearization data N-01.)

N CR LF

1

L

N

D

0

2

I

=

0 CR LF

14

(Response with the input value of linearization data N-02.)

N CR LF

1

L

N

D

0

2

O

=

0 CR LF

14

(Response with the output value of linearization data N-02.)

N CR LF

1

L

N

D

0

3

I

=

0 CR LF

14

N CR LF

1

L

N

D

1

6

I

=

0 CR LF

14

(Response with the input value of linearization data N-16.)

N CR LF

1

L

N

D

1

6

O

=

0 CR LF

14

(Response with the output value of linearization data N-16.)

R CR LF

1

Y

E

S

CR LF

Linearization data setting

L

N

D

0

1 CR LF

6

L

N

D

0

1

I

=

0 CR LF

14

Note: Setting can be made from any of the data items 01 to 16.
Note: The reading of the main unit changes to LINE the moment it receives an LND XX
command.

-

1

0

0

0 CR LF

5

L

N

D

0

1

I

=

-

1

0

0

0 CR LF

14

(Sets the input value of linearization data N-01 to -1000.)

N CR LF

1

L

N

D

0

1

O

=

0 CR LF

14

-

9

0

0 CR LF

4

L

N

D

0

1

O

=

-

9

0

0 CR LF

14

(Sets the output value of linearization data N-01 to -900.)

N CR LF

1

L

N

D

0

2

I

=

0 CR LF

14

-

5

0

0 CR LF

4

L

N

D

0

2

I

=

-

5

0

0 CR LF

14

(Sets the input value of linearization data N-02 to -500.)

N CR LF

1

L

N

D

0

2

O

=

0 CR LF

14

-

6

0

0 CR LF

4

L

N

D

0

2

O

=

-

6

0

0 CR LF

14

(Sets the output value of linearization data N-01 to -600.)



R CR LF

1

Y

E

S

CR LF

5

E

r

r

o

r

CR LF

6

(Response when a value outside the setpoint range is input.)

Note: If an R command is sent after setting required data, the main unit saves data provided
up to that moment and then returns to measurement operation.

Note: The main unit returns to measurement operation upon an R command (or returns to
the response with the full-scale reading if an N command is sent.)

Note: The main unit returns to measurement operation upon an R command (or returns to
the response with the input value of linearization data N-01 if an N command is sent.)

Note: If an R command is sent after setting required data, the main unit saves data provided
up to that point and then returns to measurement operation.

Summary of Contents for AM-215A

Page 1: ...TOR ANALOG OUT or RS485 INPUT EXC POWER c e c e c e AL1 AL2 SET POINT COMPARATOR AM 215A INSTRUCTION MANUAL Caution 1 The equipment may be damaged if the input current or voltage exceeds the maximum...

Page 2: ...y When using a 2 wire sensor terminals 2 11 should be externally connected 4 When no terminals are selected for outputting do not connect anything to vacant terminals AL1 AL2 Condition data A group of...

Page 3: ...et The default value is 9999 The default value is 9999 A menu is displayed only the option output form 4 The default value is 0 A displayed value to obtain an output from the full scale side of the an...

Page 4: ...g temperature and humidity ranges 0 to 50 C 35 to 85 RH no condensation Storage temperature and humidity ranges 20 to 70 C 60 or lower RH no condensation Supply voltage DC 24 V 20 Consumed power Appro...

Page 5: ...inearity compensation of the rectifying point 2 is inputted The input value display value before linearity compensation of the rectifying point 16 is inputted The output value display value before lin...

Page 6: ...ransmission control procedure Signal name used Number of units that can be connected Transmission line length Delimiter Parity bit Start stop Two wire half duplex polling selecting 2400 4800 9600 1920...

Page 7: ...to ON AL1 AL2 AL1 AL2 AL1 AL2 AL1 AL2 Function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Char Length 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Char Length Establishment of...

Page 8: ...0 H I CR LF 10 reading w o decimal point 5 0 0 0 H I CR LF 11 reading w decimal point 9 8 0 0 H I CR LF 10 overrange reading w o decimal point 9 8 0 0 H I CR LF 11 overrange reading w decimal point M...

Page 9: ...3 Response with the status of the hold function being remote controlled D Z R CR LF 3 Response with the status of the digital zero function being remote controlled R L Y CR LF 3 Response with the sta...

Page 10: ...T 1 W 1 CR LF 14 Response with the status of the tracking zero time being 1 and tracking zero width being 1 T R K O N T 9 9 W 9 9 CR LF 16 Response with the status of the tracking zero time being 99 a...

Page 11: ...O side logic function being set to N C N CR LF 1 L L O N O CR LF 8 Response with the status of the LO side logic function being set to N O L L O N C CR LF 8 Response with the status of the LO side log...

Page 12: ...on correction data items being 16 Setting for number of linearization L N O 0 2 CR LF 6 Y E S CR LF 5 correction data items Sets the number of linearization correction data items to 02 L N O 1 6 CR LF...

Page 13: ...unication parameter failure Note Under normal conditions this response is made only once Note ERROR B to ERROR F are available as the response commands for acknowledgment Note If a response to the ERR...

Reviews: