19
Wash Programs
27
1205
Wash Program, Cold
On starting the machine, the door will automatic-
ally be locked, the drain valve closed, the cold
water valve opened and the pre-wash carried out
as previously described, whereafter the main
wash is started.
As the main wash is started, the drain valve
closes, detergent is admitted and cold water is
filled to the level determined by the level control.
On reaching this level, cold water is closed.
The water level controlled machine will now wash
the fabrics for six minutes. The machine is then
emptied.
Cold water is filled for the first rinse which lasts
one minute, followed by spin extraction for 30
seconds.
After this extraction comes the second rinse in
cold water concluded with spin extraction, whe-
reafter the third rinse is started.
Fabric softener is automatically admitted during
the third rinse. The fabrics are rinsed with cold
water for two minutes followed by a spin extra-
ction of four minutes duration. Finally there is a
shake out for one and a half minutes.
COLD
Time Temp. Water
(Min.)
Level
Prewash
3
Cold High
Detergent 1
Drain
1
Mainwash
6
Cold High
Detergent 2
Drain
1
Rinse 1
1
Cold High
Drain
1
Extract
0.5
Rinse 2
1
Cold High
Drain
1
Extract
0.5
Rinse 3
2
Cold High
Detergent 3
Drain
1
Extract
4
Shake-out
1.5
Total time
24.5
(water fill time
not included)
Fig.
27