42
Trouble shooting
If the machine does not start
A Check the circuit breaker in the electrical
power line to the machine.
B Check the door safety switch and door lock.
C Check the glass cartridge fuses.
D Check for loose wires at the incoming power
terminal block.
If water does not drain
A Check the drain valve and drain solenoid for
proper operation.
B Disconnect the drain hose connected to the
drain line. If a full flow of water comes out, the
problem is in the main waste line. If water flow
is slow, the problem is the accumulation of
foreign materials between the drain valve and
shell outlet of machine. Clean the valve body
of any foreign objects found.