ADVANCED SETTINGS
WARNING!!
The options in this section can affect the performance of your thermostat and should only be modiied by
an experienced underloor heating installer or under the instruction of Warmup technical support.
Programmable Limit °C
Overheat Limit °C
Air
Floor
Min. Temp
Max. Temp
Min. Temp
Max. Temp
Tiles
5
30
5
40
40
Stone
3
30
5
40
40
Laminate
2
27
5
27
30
Wood
2
27
5
27
30
Carpet
2
27
5
27
30
Vinyl
5
27
2
27
30
Regulator
5
30
n/a
n/a
n/a
User deined
User deined
User deined
User deined
HEATER SETTINGS:
•
Floor type
: this setting will affect the upper and lower limits of programmable set temperatures as well as
the overheat limit. If you set a user deined limit then you are advised to check the safe temperature limits with
the looring manufacturer
•
Regulator
: This setting will change the thermostat to a regulator mode. In this mode all temperature inputs
are replaced by a setting between 1 and 10. Where the number represents the number of minutes in a 10
minute cycle that the heating will be on (ie. If set to 7 then the thermostat will be on for 7 minutes and then off
for 3 minutes before turning on again). You must reprogram the thermostat schedule after you have turned on
regulator mode.
Note: do not try to change the target heater settings if you have selected regulator.
•
Fil pilote
: This feature is speciic to the French market and is not necessary in most other locations. Here
you can turn on the il pilote mode and set the comfort, economy and frost protect temperatures. You must also
connect the system pilot wire into terminal 1.
•
Master/ relay
: This feature allows you to use one thermostat to control another. This is useful if you need to
control multiple underloor heating elements with one program. In order to set-up this feature use the following
steps:
1. Choose which thermostat will be the “master” and which will be the “relay”
2. Use low voltage electric cable to connect terminal 6 on the “master” to terminal 6 on the “relay”
3. Use low voltage electric cable to connect terminal 7 on the “master” to terminal 7 on the “relay”
Hint: on the “master” thermostat these connector cables are in addition to the loor sensor but on the
“relay” thermostat the loor sensor is not necessary
4. In advanced settings of each thermostat switch the “master” thermostat to master mode and the “re-
lay” thermostat to relay mode
5. Program desired schedule into the “master” thermostat
The “relay” thermostat will no longer use its sensors for thermal regulation. It will now turn on/ off in tan-
dem with the “master” thermostat.