background image

HOLIDAY MODE

HOLIDAY MODE allows you to over-ride your schedule with a ixed tem-

perature for a prolonged period of time. This can help save energy if you 

know that you will be out of the house and require minimal heating.

Press the highlighted button next to “holiday mode” to access the menu.

Press “up” or “down” to set the irst day you would like HOLIDAY MODE to 

start.

Press “holiday end at” and then press “up” or “down” to set the day when 

you would like holiday mode to stop. At the end of the HOLIDAY MODE 

your program will return to the current settings. If you would like HOLIDAY 

MODE to continue indeinitely, leave the end date as “not speciied”.

Press “holiday temperature” to set the ixed temperature that will be held 

for the entire HOLIDAY MODE period. 

Pressing “OK” will conirm the selection and HOLIDAY MODE will start at 

12:00 pm on the speciied date.

During the HOLIDAY MODE you will have a modiied home screen. To 

cancel the HOLIDAY MODE at any time just press “cancel”.

If you want to return to HOLIDAY MODE you will need to set it again.

ENERGY MONITOR

Your thermostat monitors the amount of energy your underloor heating 

system is using, you can use these pages to view the amount of energy 

used and set parameters to determine the cost of that energy.

To access this menu press “energy monitor”

If you want to see how much energy you have used, select “view energy 

use” and then select the time period you would like to review

NOTE: if you see the “load settings” option you will need to enter the 

total power in watts of the underloor heating system connect to the 

thermostat. If you are unclear about the power of your underloor 

heating then contact your installer.

On the graph each red bar indicates a time period (in this case it is 

months). The height of the bar indicates that amount of energy in KWH 

used by the underloor heating system during that period. The bar in the 

far right is the most recent time period and the bar on the far left is the 

oldest.  The total amount of energy used in the entire time span is dis-

played in the bottom bar.

Press “OK” to return to the ENERGY MONITOR page.

Summary of Contents for 3IE

Page 1: ...help button for more infor mation on the options available If you do not press any button on the thermostat for 1 minute then it will go to standby mode In standby mode the screen will be dimmed but the thermostat will continue to function as normal To exit standby mode press wake The button on bottom of the 3IE button 7 is the power button You can turn off your thermostat and Warmup underloor hea...

Page 2: ...ost with low interest rates PRICE MATCH always get the best deals available Boilers Radiators Heating controls Pipes ittings Cylinders Fires Renewable energy Bathroom suites Kitchen sinks taps Showers Wet rooms Towel warmers Bathroom furniture much more H U G E R E D U C T I O N S we have ON THOUSANDS OF ITEMS 0 8 4 4 8 0 0 3 4 6 0 CALL US ON visit our website plumbnation co uk ...

Page 3: ...energy overnight Note if you do not need the heating to protect against frost then you can scroll down to the bottom of the temperature range to set the target temperature to OFF With this setting the heating will not come on regardless of the temperature Once you have set all the desired periods in the day press done to go to the summary page This summary page allows you to see the program you ha...

Page 4: ...Press up and down until the day that you would like to view is highlight ed then press OK to view that day To exit the VIEW EDIT PROGRAM menu page press back Note that if you have edited any days these changes will be saved Here you can view the heating schedule for the selected day If you would like to change any of the heating periods press edit Remember that you will have to set all the heating...

Page 5: ... time just press cancel If you want to return to HOLIDAY MODE you will need to set it again ENERGY MONITOR Your thermostat monitors the amount of energy your underloor heating system is using you can use these pages to view the amount of energy used and set parameters to determine the cost of that energy To access this menu press energy monitor If you want to see how much energy you have used sele...

Page 6: ...your energy cost is 11 6 pence per KWH then you will need to set your cost per KWH to 0 116 If you are setting a standard low energy tariff you will also need to set the time of day at which the low energy tariff starts and stops and the cost per KWH during the low tariff period After all these parameters are set you can view the cost of the energy used by your underloor heating system in view cos...

Page 7: ... When child lock is on you will need to hold wake continuously for 10 seconds in order to exit standby mode SET HEATING TARGET Your thermostat is capable of using a loor temperature sensor air tem perature sensor or both for thermal regulation If you are using your underloor heating as secondary heating source such as in the bathroom then you might prefer to use the loor temperature However if the...

Page 8: ...stat schedule after you have turned on regulator mode Note do not try to change the target heater settings if you have selected regulator Fil pilote This feature is speciic to the French market and is not necessary in most other locations Here you can turn on the il pilote mode and set the comfort economy and frost protect temperatures You must also connect the system pilot wire into terminal 1 Ma...

Page 9: ...nt module for 10 seconds Warmup Plc 702 Tudor Estate Abbey Road London NW10 7UW T 0845 345 2288 International 44 208 453 6868 F 0845 345 2299 E mail uk warmup com Website www warmup co uk WARRANTY Warmup plc warrants this product to be free from defects in the workmanship or materials under normal use and service for a period of three 3 years from the date of purchase by the consumer If at any tim...

Reviews: